Skip to main content
Log in

Some applications of the use of the reflectance photodensitometer to spot test analysis

  • Published:
Microchimica Acta Aims and scope Submit manuscript

Summary

The colour developed during certain spot tests has been measured using a reflectance photodensitometer. In this way a quantitative estimation of the amount of substances present in the test solution has been made. The relationship between densitometer reading and concentration of test substance, and the best method of obtaining uniform colour in the spots are discussed. Several substances have been analysed by this method, for which only 5 to 10Μl of solution are required. 5 to 0.2 Μg of metallic ions, 100 to 5Μg of polyamide and 1 to 0.05 micro-equivalents of amino nitrogen can be determined. Precision compares well with other colorimetric methods.

Zusammenfassung

Die bei einigen Tüpfelreaktionen entwickelte Farbe wurde mit einem Reflexions-Photodensitometer gemessen. Dies ermöglicht eine quantitative Beurteilung der in der Probelösung vorhandenen Menge Substanz. Das VerhÄltnis zwischen den Densitometerablesungen und der Konzentration der Probelösung sowie die beste Methode der Herstellung gleichmÄßig gefÄrbter Tüpfelflecke werden besprochen. Mehrere Substanzen wurden mit Hilfe dieser nur 5 bis 10Μl benötigenden Methode untersucht. 5 bis 0,2Μg eines Metall-Ions, 100 bis 5Μg eines Polyamids und 1 bis 0,05 Mikro-Val Amino-Stickstoff können bestimmt werden. Ein Vergleich der Genauigkeit der Methode mit der anderer kolorimetrischer Methoden fÄllt vorteilhaft aus.

Résumé

A l'aide d'un photodensimètre à réflexion, on a mesuré la couleur qui apparaÎt au cours de certains essais à la touche. Il a été ainsi possible d'estimer quantitativement les teneurs de substances présentes dans des solutions soumises à l'étude. Les relations existant entre les lectures densitométriques et les concentrations des substances étudiées sont discutées par l'auteur ainsi que la meilleure méthode d'obtention de taches de couleurs uniformes. Plusieurs substances ont été analysées à l'aide de cette méthode qui ne nécessite que 5 à 10Μl de solution; on peut ainsi doser 5 à 0,2Μg d'ions métalliques, 100 à 5Μg de polyamides et 1 à 0,05 microéquivalents d'azote aminé. La précision obtenue est comparable à celle des autres méthodes colorimétriques.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. B. Fisher, D. S. Parsons andG. A. Morrison, Nature161, 764 (1948).

    Google Scholar 

  2. E. Beerstecher, Analyt. Chemistry22, 1200 (1950).

    Google Scholar 

  3. T. Wieland andL. Wirth, Angew. Chem.63, 171 (1951).

    Google Scholar 

  4. R. J. Block, Science108, 608 (1948).

    Google Scholar 

  5. B. N. Bull, H. W. Hahn andV. H. Baptist, J. Amer. Chem. Soc.71, 550 (1949).

    Google Scholar 

  6. L. B. Rockland, J. L. Blatt andM. S. Dunn, Analyt. Chemistry23, 1142 (1951).

    Google Scholar 

  7. S. V. Vaeck, Analyt. Chim. Acta10, 48 (1954).

    Google Scholar 

  8. S. V. Vaeck, Analyt. Chim. Acta12, 443 (1955).

    Google Scholar 

  9. S. V. Vaeck, Nature172, 213 (1953).

    Google Scholar 

  10. E. F. McFarren, Kathleen Brand andH. R. Rutkawski, Analyt. Chemistry23, 1146 (1951).

    Google Scholar 

  11. R. S. Block, Analyt. Chemistry22, 1327 (1950).

    Google Scholar 

  12. A. C. Bladine andL. F. Leloir, Analyt. Chemistry24, 1024 (1952).

    Google Scholar 

  13. E. H. Winslow andH. A. Liebhafsky, Analyt. Chemistry21, 1338 (1949).

    Google Scholar 

  14. A. L. Latner, L. Molyneux andJ. Dudfield Ross, J. Lab. Clin. Med.43, 157 (1954).

    Google Scholar 

  15. P. Kubelka andF. Munk, Z. techn. Physik12, 593 (1931).

    Google Scholar 

  16. CompareF. Feigl, Spot Tests, 4th ed., Vol. I. Amsterdam: Elsevier. 1954. p. 145, 169.

    Google Scholar 

  17. J. Lambert, Analyt. Chemistry26, 558 (1954).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ayers, C.W. Some applications of the use of the reflectance photodensitometer to spot test analysis. Mikrochim Acta 44, 1333–1349 (1956). https://doi.org/10.1007/BF01223538

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01223538

Keywords

Navigation