Summary
The colour developed during certain spot tests has been measured using a reflectance photodensitometer. In this way a quantitative estimation of the amount of substances present in the test solution has been made. The relationship between densitometer reading and concentration of test substance, and the best method of obtaining uniform colour in the spots are discussed. Several substances have been analysed by this method, for which only 5 to 10Μl of solution are required. 5 to 0.2 Μg of metallic ions, 100 to 5Μg of polyamide and 1 to 0.05 micro-equivalents of amino nitrogen can be determined. Precision compares well with other colorimetric methods.
Zusammenfassung
Die bei einigen Tüpfelreaktionen entwickelte Farbe wurde mit einem Reflexions-Photodensitometer gemessen. Dies ermöglicht eine quantitative Beurteilung der in der Probelösung vorhandenen Menge Substanz. Das VerhÄltnis zwischen den Densitometerablesungen und der Konzentration der Probelösung sowie die beste Methode der Herstellung gleichmÄßig gefÄrbter Tüpfelflecke werden besprochen. Mehrere Substanzen wurden mit Hilfe dieser nur 5 bis 10Μl benötigenden Methode untersucht. 5 bis 0,2Μg eines Metall-Ions, 100 bis 5Μg eines Polyamids und 1 bis 0,05 Mikro-Val Amino-Stickstoff können bestimmt werden. Ein Vergleich der Genauigkeit der Methode mit der anderer kolorimetrischer Methoden fÄllt vorteilhaft aus.
Résumé
A l'aide d'un photodensimètre à réflexion, on a mesuré la couleur qui apparaÎt au cours de certains essais à la touche. Il a été ainsi possible d'estimer quantitativement les teneurs de substances présentes dans des solutions soumises à l'étude. Les relations existant entre les lectures densitométriques et les concentrations des substances étudiées sont discutées par l'auteur ainsi que la meilleure méthode d'obtention de taches de couleurs uniformes. Plusieurs substances ont été analysées à l'aide de cette méthode qui ne nécessite que 5 à 10Μl de solution; on peut ainsi doser 5 à 0,2Μg d'ions métalliques, 100 à 5Μg de polyamides et 1 à 0,05 microéquivalents d'azote aminé. La précision obtenue est comparable à celle des autres méthodes colorimétriques.
Similar content being viewed by others
References
R. B. Fisher, D. S. Parsons andG. A. Morrison, Nature161, 764 (1948).
E. Beerstecher, Analyt. Chemistry22, 1200 (1950).
T. Wieland andL. Wirth, Angew. Chem.63, 171 (1951).
R. J. Block, Science108, 608 (1948).
B. N. Bull, H. W. Hahn andV. H. Baptist, J. Amer. Chem. Soc.71, 550 (1949).
L. B. Rockland, J. L. Blatt andM. S. Dunn, Analyt. Chemistry23, 1142 (1951).
S. V. Vaeck, Analyt. Chim. Acta10, 48 (1954).
S. V. Vaeck, Analyt. Chim. Acta12, 443 (1955).
S. V. Vaeck, Nature172, 213 (1953).
E. F. McFarren, Kathleen Brand andH. R. Rutkawski, Analyt. Chemistry23, 1146 (1951).
R. S. Block, Analyt. Chemistry22, 1327 (1950).
A. C. Bladine andL. F. Leloir, Analyt. Chemistry24, 1024 (1952).
E. H. Winslow andH. A. Liebhafsky, Analyt. Chemistry21, 1338 (1949).
A. L. Latner, L. Molyneux andJ. Dudfield Ross, J. Lab. Clin. Med.43, 157 (1954).
P. Kubelka andF. Munk, Z. techn. Physik12, 593 (1931).
CompareF. Feigl, Spot Tests, 4th ed., Vol. I. Amsterdam: Elsevier. 1954. p. 145, 169.
J. Lambert, Analyt. Chemistry26, 558 (1954).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ayers, C.W. Some applications of the use of the reflectance photodensitometer to spot test analysis. Mikrochim Acta 44, 1333–1349 (1956). https://doi.org/10.1007/BF01223538
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01223538