Skip to main content
Log in

A co-precipitation and spectrophotometric determination of micro-quantities of iron in Japanese brewing water and liquor

  • Published:
Microchimica Acta Aims and scope Submit manuscript

Summary

Co-precipitation and spectrophotometric determination of microquantities of iron in the Japanese brewing water, “Miya mizu”, and in the Japanese liquor, “Saké”, have been investigated. Iron was collected from brewing water by co-precipitation with manganese dioxide, and was then determined spectrophotometrically witho-phenanthroline. The error of the method was about 0.1 μg Fe in 500 ml, or 0.0002 ppm Fe, which corresponds to a relative error of about 20%. The brewing water “Miya mizu” investigated contains a very small quantity of iron, e. g., from 0.0001 to 0.0006 ± 0.0002 ppm of iron. Samples of “Saké” were ashed with sulphuric and nitric acids, and the procedure as for brewing water was followed. Pyrophosphate had no effect. The error in this case was about 0.005 ppm Fe, which corresponds to 0.25 μg Fe in 50 ml or to a relative error of 2%. “Saké” contains, for example, 0.263 ±0.005 ppm of iron.

Zusammenfassung

Die Mitfällung und spektrophotometrische Bestimmung von Mikromengen Eisen in dem japanischen Brauereiwasser „Miya mizu“ und in dem japanischen Reisbier „Saké“ wurde untersucht. Das Eisen wurde durch Mitfällung mit Mangandioxyd aus „Miya mizu“ angereichert und dann mit o-Phenanthrolin spektrophotometrisch bestimmt. Der Fehler dieses Verfahrens betrug etwa 0,1 μg Fe für 500 ml bzw. 0,0002 ppm. Dies entspricht einer relativen Abweichung von etwa 20%. Das untersuchte „Miya mizu“ enthält nur sehr kleine Eisenmengen in der Größenordnung von 0,0001 bis 0,0006 ± 0,0002 ppm. Die „Saké“-Proben wurden mit Schwefelsäure und Salpetersäure verascht und weiter in gleicher Weise aufgearbeitet. Die Anwesenheit von Pyrophosphat hatte keinen störenden Einfluß auf das Verfahren. Der Fehler betrug in diesem Fall etwa 0,005 ppm Fe; dies entspricht 0,25 μg Fe in 50 ml bzw. einer relativen Abweichung von 2%. „Saké“ enthält beispielsweise 0,263 ± 0,005 ppm Fe.

Résumé

On a étudié le dosage par co-précipitation et par spectrophotométrie de microquantités de fer dans l'eau de brasserie japonaise »Miya mizu« et dans la liqueur japonaise » Saké«. On a recueilli le fer de l'eau de brasserie par co-précipitation avec le bi-oxyde de manganèse et on l'a dosé par spectrophotométrie avec l'o-phénanthroline. L'erreur de la méthode est d'environ 0,1 μg Fe pour 500 ml, soit 0,0002 p. p. m. Fe, ce qui correspond à une erreur relative d'environ 20%. L'eau de brasserie »Miya mizu« étudiée contient une très petite quantité de fer, environ 0,0001 à 0,0006 ± 0,0002 p. p. m. de fer. On a fait les cendres sulfuriques et nitriques avec les échantillons de »Saké« et l'on a ensuite suivi le même processus que pour l'eau de brasserie. Les pyrophosphates étaient sans effet. Dans ce cas, l'erreur était d'environ 0,005 p. p. m. de fer, ce qui correspond à 0,25 μg Fe dans 50 ml, soit une erreur relative de 2%. Le »Saké« contient par exemple 0,263 ± 0,005 p. p. m. de fer.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature

  1. S. Kano, J. Agric. Chem. Soc. Japan27, 881 (1953).

    Google Scholar 

  2. H. Kruse, Gas- u. Wasserfach90, 109 (1949); Chem. Abstr.43, 5139 b (1949).

    Google Scholar 

  3. H. Nishida, Japan Analyst3, 250 (1954).

    Google Scholar 

  4. N. W. Rakestraw, H. E. Mahncke, andE. F. Beach, Ind. Eng. Chem., Analyt. Ed.8, 136 (1936).

    Google Scholar 

  5. H. N. Stokes andJ. R. Cain, J. Amer. Chem. Soc.29, 409 (1907).

    Google Scholar 

  6. E. B. Sandell, Colorimetric Determination of Traces of Metals, 2nd Ed. New York: Interscience. 1953. p. 362.

    Google Scholar 

  7. O. D. Snell andC. T. Snell, Colorimetric Methods of Analysis, 3rd Ed., Vol. 2. Princeton: Van Nostrand. 1957. p. 279.

    Google Scholar 

  8. L. Deibner andH. Bouzigues, Mikrochim. Acta [Wien]1954, 501.

  9. B. H. Nissen, Amer. Soc. Brewing Chem., Proc.11, 32 (1946).

    Google Scholar 

  10. S. H. Jackson, Ind. Eng. Chem., Analyt. Ed.10, 302 (1938).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Work done under the auspices of the Nadagogo Brewing Guild.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Otozai, K., Mizumoto, K. A co-precipitation and spectrophotometric determination of micro-quantities of iron in Japanese brewing water and liquor. Mikrochim Acta 49, 217–226 (1961). https://doi.org/10.1007/BF01217049

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01217049

Keywords

Navigation