  • Published:
Microchimica Acta Aims and scope Submit manuscript

Summary

A small-sizeDumas nitrometer of 0.2-ml capacity, graduated in microliters, and permitting estimation of tenths of microliters, has been described. The 0.4-mg samples are weighed on the Garner quartz fiber balance. The standard error of estimate from 10 serial analyses with 0.4-mg samples of azobenzene was computed equal to ±0.28% N. For 0.1-mg samples the corresponding figure is ±0.96% N, but it should be possible to improve this value.

Zusammenfassung

Ein Azotometer wird beschrieben, dessen Meßrohr in Mikroliter geteilt ist und einen Gesamtinhalt von 0,2 ml hat. Zehntel-Mikroliter können geschätzt werden. Einwaagen von 0,4 mg Substanz werden mit der Garner Mikrowaage vorgenommen. Der mittlere Fehler einer Einzelbestimmung wurde aus den Ergebnissen von zehn Azobenzol-Analysen zu ±0,28% Stickstoffermittelt. Die entsprechende Zahl für 0,1-mg-Proben, ±0,96% Stickstoff, dürfte einer Verbesserung zugänglich sein.

Résumé

On décrit un petit nitromètreDumas de 0,2 ml de capacité, gradué en microlitres et permettant l'estimation de dixièmes de microlitres. Les échantillons de 0,4 mg sont pesés sur la microbalance à fil de quartz de Garner. L'erreur standard déterminée sur 10 analyses en série avec des prises de 0,4 mg d'azobenzène est estimée à ±0,28% N. Pour des prises d'essai de 0,1 mg le chiffre correspondant est ±0,96 N, niais il doit être possible d'améliorer cette valeur.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature cited

  1. J. A. Kuck, P. L. Altieri andA. K. Towne, Mikrochim. Acta [Wien]1953, 254.

  2. J. A. Kuck, P. L. Altieri andA. K. Towne, Mikrochim. Acta [Wien]1954, 1.

  3. K. Linderstrøm-Lang andH. Holter, Z. physiol. Chem.220, 5 (1933).

    Article  Google Scholar 

  4. D. Bruel, H. Halter, K. Linderstrøm-Lang andK. Rozita, C. r. trav. lab. Carlsberg, Sér, Chim.25, No. 13, 289 (1946).

    CAS  Google Scholar 

  5. E. Tompkins andP. Kirk, J. Biol. Chem.142, 447 (1942).

    Google Scholar 

  6. J. A. Kuck, A. Kingsley, D. Kinsey, F. Sheehan andG. F. Swigert Analyt. Chemistry.22, 604 (1950).

    Article  CAS  Google Scholar 

  7. B. Grunbaum, F. Schaffer andP. Kirk, Analyt. Chemistry24. 1487 (1952).

    Article  Google Scholar 

  8. W. Kirsten andB. Wallberg-Olausson, Analyt. Chemistry23, 927 (1951).

    Article  CAS  Google Scholar 

  9. J. Niederl, O. Trautz andW. Saschek, Mikrochem., Emich-Festschr. 219 (1930).

  10. W. Saschek, Ind. Eng. Chem., Analyt. Ed.3, 198 (1931).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kuek, J.A., Altieri, P.L. Dumas nitrogen determination with decimilligram samples. Mikrochim Acta 42, 17–24 (1954). https://doi.org/10.1007/BF01215566

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01215566

Keywords

Navigation