Summary
Various organic coatings on spectroscopic graphite as well as several types of uncoated graphite materials were examined as sensors in the precipitation titration of nitroform and perchlorate vs. cetylpyridinium chloride. The polymer used in the coatings was poly(vinyl chloride). The plasticizer of choice was di(ethylhexyl) phthalate (dioctylphthalate) because of its low toxicity and large endpoint breaks. Other plasticizers such as nitrobenzene, tricresyl-phosphate, and phthalates with an alkyl chain length between 4 and 8 carbon atoms are also suitable. The plastic-coated sensors yielded larger breaks than any of the uncoated graphite sensors. Of the latter materials, Poco AXF-9Q graphite yielded the largest breaks for both anions examined. Coated and uncoated graphite electrodes can be used as sensors in a variety of potentiometric titrations. While these electrodes are not selective per se, selectivity is governed by the analyte/titrant interaction.
Zusammenfassung
Verschiedene organische Schichten wurden spektroskopisch auf reinem sowie auf einigen Arten von unbeschichteten Graphit hinsichtlich ihrer Verwendung als Sensoren für die Fällungstitration von Nitroform und Perchlorat mit Cetylpyridiniumchlorid untersucht. Als Beschichtung wurde Polyvinylchlorid eingesetzt. Als Weichmacher wurde Diethyl-Hexyl-Phthalat (Dioctyl-Phthalat) wegen seiner geringen Toxizität und großen Potentialsprünge im Titrationsendpunkt gewählt. Andere Weichmacher wie Nitro-benzol, Tri-Kresylphosphat und Phthalate mit einer Alkyl-Kettenlänge von 4 bis 8 sind ebenfalls geeignet. Die kunststoffbeschichteten Sensoren lieferten größere Potentialsprünge als alle unbeschichteten Graphit-Sensoren. Von den letzteren Materialien zeigte POCO AXF-90 Graphit die größten Potentialsprünge für beide untersuchten Anionen. Beschichtete und unbeschichtete Graphitelektroden können als Sensoren für eine Vielfalt potentiometrischer Titrationen eingesetzt werden. Während die Elektroden selbst nicht selektiv sind, ist die Selektivität durch die Wechselwirkung Titrator/ Titrand gegeben.
Similar content being viewed by others
References
W. Selig, Analyt. Letters15, 309 (1982).
W. Selig, Mikrochim. Acta [Wien]1978 II, 75.
T. Higuchi, C. R. Illian, and J. L. Tossounian, Analyt. Chemistry42, 1674 (1970).
W. Selig, Microchem. J.25, 200 (1980).
T. Higuchi, U. S. Patent 3,843,305 (22 October 1974); Chem. Abstr.82, P25497y (1975).
S. Srianujata, W. R. White, T. Higuchi, and L. A. Sternson, Analyt. Chemistry50, 232 (1978).
S. H. Hoke and A. G. Collins, Report1979, BETC/RI-79/10; Chem. Abstr.93, 18641q (1980).
G. C. Dilley, Analyst105, 713 (1980).
M. J. M. Campbell, B. Demetriou, and R. Jones, Analyst105, 605 (1980).
K. Vytras, M. Dajkova, and M. Remes, Cesk. Farm.30, 61 (1981).
K. Vytras, M. Remes, and H. Kubesova-Svobodova, Analyt. Chim. Acta124, 91 (1981).
K. Vytras, M. Dajkova, and V. Mach, Analyt. Chim. Acta127, 165 (1981).
F. J. Miller, Analyt. Chemistry35, 929 (1963).
P. F. Thomason, Microchem. J.8, 234 (1964).
A. Dodson and V. J. Jennings, Analyt. Chim. Acta72, 205 (1975).
T. J. Pastor, V. J. Vajgand, and Z. Simonovic, Analyt. Chim. Acta98, 233 (1978).
J. Bercik, Z. Hladky, and M. Cakrt, Z. analyt. Chem.261, 113 (1972).
E. Siska and E. Pungor, Z. analyt. Chem.257, 12 (1971).
W. Selig, Mikrochim. Acta [Wien]1979 II, 373.
Author information
Authors and Affiliations
Additional information
This work was performed under the auspices of the U. S. Department of Energy at Lawrence Livermore National Laboratory under contract number W-7405-ENG-48.
Rights and permissions
About this article
Cite this article
Selig, W. Comparison of various sensors in the potentiometric microdetermination of nitroform and perchlorate with cetylpyridinium chloride. Mikrochim Acta 79, 333–345 (1983). https://doi.org/10.1007/BF01204816
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01204816