Summary
Some precipitation titrations have been evaluated for the determination of the oxo anions of selenium and tellurium. Selenite and tellurite can be titrated with sodium diethyldithiocarbamate, using a silver ion-selective electrode as sensor. Tellurite can be titrated with cetylpyridinium chloride, using a poly(vinylchloride)/dioctylphthalate-coated graphite rod as sensor.
Silver nitrate can be used to titrate selenite, tellurite, and tellurate. While the sum of tellurite and tellurate can be estimated, no sequential titration is possible. Lead nitrate can be used for the titration of selenite in the presence of selenate, in aqueous solution. In 80% methanolic solution the sum of selenite and selenate is titrated with lead nitrate.
Similar content being viewed by others
References
M. R. Massen, Mikrochim. Acta [Wien]1976 I, 399.
W. S. Selig, Microchem. J.32, 125 (1985).
W. Selig, Anal. Lett.15 (A3), 309 (1982).
W. Selig, Mikrochim. Acta [Wien]1983 I, 333.
W. Selig, Mikrochim. Acta [Wien]1978 II, 75.
E. E. Chao and K. L. Cheng, Anal. Chem.48, 267 (1976).
L. G. Sillen and A. E. Martell (compilers), Stability Constants of Metal-Ion Complexes, Special Publication No. 17. London: The Chemical Society. 1964.
E. Högfeldt (compiler), Stability Constants of Metal-Ion Complexes. Part A: Inorganic Ligands. Oxford: Pergamon Press. 1982.
Gmelin Handbuch der Anorganischen Chemie, 8th ed., Tellur, Ergänzungsband Teil B1. Berlin: Springer. 1976, p. 142.
H. Bode, Fresenius' Z. Anal. Chem.134, 100 (1951).
W. S. Selig, Fresenius' Z. Anal. Chem.312, 419 (1982).
S. S. M. Hassan and M. M. Habib, Microchem. J.26, 181 (1981).
S. S. M. Hassan and M. M. Habib, Analyst106, 1281 (1981).
Author information
Authors and Affiliations
Additional information
This work performed under the auspices of the U. S. Department of Energy by the Lawrence Livermore National Laboratory under contract No. W-7405-ENG-48.