Summary
Capabilities of liquid-liquid extraction systems without organic solvents have been examined. Ternary poly(ethylene glycol)-inorganic salt-water systems have been proposed for extraction of complexes of metals with water-soluble organic reagents and inorganic ligands.
Phase diagrams for such two-phase systems have been studied. The distribution of some inorganic ions and organic reagents in PEG 2000-ammonium sulphate systems has been examined at different pH values of the salt-phase. It is shown that the distribution coefficients are lower than unit for all the cations studied while reagents, containing aromatic rings, are extracted into the PEG-phase with distribution coefficients higher than one hundred. Conditions are reported which provide effective extraction of iron(III) in presence of several water-soluble photometric reagents. Extraction in the PEG 2000-ammonium sulphate-water system in presence of ammonium thiocyanate and sulphuric acid has been studied. Copper, zinc, cobalt, iron(III), indium, molybdenum(V) are extracted into the PEG-phase with high distribution coefficients.
Zusammenfassung
Die Eignung von Flüssig-flüssig-Extraktions-Systemen ohne organisches Lösungsmittel wurde geprüft. Ternäre Systeme aus Polyethylenglykol-anorganischem Salz-Wasser wurden für die Extraktion von Metallkomplexen mit wasserlöslichen organischen Reagenzien und anorganischen Liganden vorgeschlagen.
Die Phasendiagramme solcher Zwei-Phasen-Systeme wurden untersucht. Die Verteilung einiger anorganischer Ionen und organischer Reagenzien in Polyethylenglykol (PEG) 2000-Ammoniumsulfat-Systemen wurde bei verschiedenem pH der Salzphase geprüft. Dabei ergab sich, daß die Verteilungskoeffizienten für alle untersuchten Kationen geringer sind als eins, während Reagenzien, die einen aromatischen Ring enthalten, in die PEG-Phase mit Verteilungskoeffizienten über 100 extrahiert werden. Versuchsbedingungen für die wirkungsvolle Extraktion von Fe(III) in Gegenwart verschiedener wasserlöslicher photometrischer Reagenzien wurden angegeben. Die Extraktion mit PEG 2000-Ammoniumsulfat-Wasser in Gegenwart von Ammoniumrhodanid und Schwefelsäure wurde untersucht. Kupfer, Zink, Kobalt, Eisen (III), Indium und Molybdän werden mit hohem Verteilungskoeffizienten in die PEG-Phase extrahiert.
Similar content being viewed by others
References
P.-A. Albertsson, Partition of Cell Particles and Macromolecules. Moscow: Mir. 1974. p. 381.
H. Eisenberg and G. Ram Mohan, J. Phys. Chem.63, 5, 671 (1959).
H. Eisenberg and E. F. Casassa, J. Polym. Sci.47, 29 (1960).
T. I. Zvarova, V. M. Shkinev, B. Ya. Spivakov, and Yu. A. Zolotov, Dokl. Akad. Nauk SSSR273, 107 (1983).
Yu. A. Zolotov and V. V. Bagreev, Zh. Analit. Khimii6, 649 (1966).
V. I. Kuznetsov and S. B. Savvin, Dokl. Acad. Nauk SSSR273, 107 (1983).
S. B. Savvin, Organic Reagents of Arsenazo III Group. Moscow: Atomizdat. 1971. p. 58.