Position control and extra-column effects of a microelectrode detector in open-tubular column liquid chromatography

  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

A liquid chromatography system with a potentiometric microelectrode at the exit end of an open-tubular LC column of 3.5μm i. d. nearly shows the theoretically [2, 10] predicted performance of 980 000 theoretical plates for non-retained components at a retention time of a few minutes. Possibilities of controlling the position of the microelectrode tip are given. A distance of one column i. d. between detector and column leads to a loss in column performance of about 15%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. C. Gluckman, M. Novotny,J. Chromatogr. Library 1985,30, 57.

    Google Scholar 

  2. J. H. Knox, M. T. Gilbert,J. Chromatogr. 1979,186, 405.

    Google Scholar 

  3. A. Manz, W. Simon, in:Microcolumn Separations (M. V. Novotny, D. Ishii, eds.), Journal of Chromatography Library, Vol. 30, Elsevier, Amsterdam-Oxford-New York-Tokyo, 1985, p. 297.

    Google Scholar 

  4. K. šlais, M. Krejčí,J. Chromatogr. 1982,235, 21.

    Google Scholar 

  5. F. Yang,J. Chromatogr. Sci. 1982,20, 241.

    Google Scholar 

  6. M. J. Sepaniak, J. D. Vargo, C. N. Kettler, M. P. Maskarinec,Anal. Chem. 1984,56, 1252.

    Google Scholar 

  7. H. P. M. Van Vliet, H. Poppe,J. Chromatogr. 1985,346, 149.

    Google Scholar 

  8. F. Zarrin, N. J. Dovichi,Anal. Chem. 1985,57, 1826.

    Google Scholar 

  9. J. G. White, R. L. St. Claire, J. W. Jorgenson,Anal. Chem. 1986,58, 293.

    Google Scholar 

  10. A. Manz, W. Simon,Anal. Chem. 1987,59, 74.

    Google Scholar 

  11. J. E. Sandifer, R. P. Buck,J. Electroanal. Chem. 1974,56, 385.

    Google Scholar 

  12. R. P. Buck,Ion-Selective Electrode Rev. 1982,4, 3.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Manz, A., Simon, W. Position control and extra-column effects of a microelectrode detector in open-tubular column liquid chromatography. Mikrochim Acta 88, 147–158 (1986). https://doi.org/10.1007/BF01196607

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01196607

Key words

Navigation