Summary
Methods like dipole source localization require an exact specification of the co-ordinates of electrode positions. Different values for the co-ordinates of F3, F4, P3 and P4 are encountered in literature. This is due to the,unexpected complexity of the calculations involved and aggravated by an inaccurate but widely used control procedure for the placement of these electrodes. We present a table of co-ordinates for the 10–20 system together with a method for determining the co-ordinates of mid-way positions within the 10–20 system. The consequence of using erroneous co-ordinates on the accuracy of dipole source localization is discussed.
Similar content being viewed by others
References
Cooper, R., Osselton, J.W. and Shaw, J.C. EEG technology. Butterworths, London. 1980 (3rd edition).
Dawson, G.D. Auto-correlation and automatic integration. Electroenceph. clin. Neurophysiol., 1954, Suppl. 4: 26–37.
De Munck, J.C., Vijn, P.C.M. and Spekreijse, H. A practical method for determining electrode positions on the head. Electroenceph. clin. Neurophysiol., 1991, 78: 85–87.
Echallier, J.F., Perrin, F. and Pernier, J. Computer-assisted placement of electrodes on the human head. Electroenceph. clin. Neurophysiol., 1992, 82: 160–163.
Jasper H.H. The 10–20 electrode system of the International Federation. Electroenceph. clin. Neurophysiol., 1958, 10: 370–375.
Kavanagh R.H., Darcey, T.M., Lehmann D. and Fender, D.H. Evaluation of methods for three-dimensional localization of electrical sources in the human brain. IEEE-BME, 1978, 25: 421–429.
Law, S.K. and Nunez, P.L. Quantitative representation of the upper surface of the human head. Brain Topography, 1991, 3: 365–371.
Perrin, F., Pernier, J., Bertrand, O., Giard, M.-H. and Echalier, J.F. Mapping of scalp potentials by surface spline interpolation. Electroenceph. clin. Neurophysiol., 1987, 66: 75–81.
Rush, S. and Discroll, D.A. Current distribution in the brain from surface electrodes. Anesth. Analg., 1968, 47: 717.
Thickbroom, G.W., Mastaglia, F.L. and Carroll, W.M. Spatiotemporal mapping of evoked cerebral activity, Electroenceph. clin. Neurophysiol., 1984, 59: 425–431.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Böcker, K.B.E., van Avermaete, J.A.G. & van den Berg-Lenssen, M.M.C. The international 10–20 system revisited: Cartesian and spherical co-ordinates. Brain Topogr 6, 231–235 (1994). https://doi.org/10.1007/BF01187714
Accepted:
Issue Date: