In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography

  • Articles
  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Previous studies indicate that conventional geometric edge detection techniques, used in quantitative coronary arteriography (QCA), have significant limitations in quantitating coronary cross-sectional area of small diameter (D) vessels (D<1.00 mm) and lesions with complex cross-section. As a solution to this problem, we have previously reported on an in-vitro validation of a videodensitometric technique that quantitates the absolute cross-sectional area including small vessel diameter (D<1.00 mm) and any complex shape of the vessel cross-section. For in-vivo validation, plastic tubing (5–8 mm long) with different shape complex cross-section with known cross-sectional area (A=0.8–4.5 mm2) were percutaneously wedged in the coronary arteries of anesthetized pigs (40–50 kg). Contrast material injections (6–10 ml at 2–4 ml/sec) were made into the left main coronary artery during image acquisition using a motion immune dual-energy subtraction technique, where low and high X-ray energy and filtration were switched at 30 Hz. A comparison was made between the actual and measured cross-sectional area using the videodensitometry and edge detection techniques in tissue suppressed energy subtracted images. In eighteen comparisons the videodensitometry technique produced significantly improved results (slope=0.87, intercept=0.24 mm2, r=0.94) when compared to the edge detection technique (slope=0.42, intercept=1.99 mm2, r=0.39). Also, a cylindrical vessel phantom (D=1.00–4.75 mm) was used to test the ability to calculate and correct for the effect of the out of plane angle of the arterial segment on the cross-sectional area estimation of the videodensitometry technique. After corrections were made for the out of plane angle using two different projections, there was a good correlation between the actual and the measured cross-sectional area using the videodensitometry technique (slope=0.91, intercept=0.11 mm2, r=0.99). These data suggest that it is possible to quantitate absolute cross-sectional area without any assumption regarding the arterial shape using videodensitometry in conjunction with the motion immune dual-energy subtraction technique.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Detre KM, Wright E, Murphy ML, Takaro T. Observer agreement in evaluating coronary angiograms. Circulation 1975; 52: 979–86.

    PubMed  Google Scholar 

  2. Zir LM, Miller SW, Dinsmore RE, Gilbert JP, Hawthorne JW. Interobserver variability in coronary angiography. Circulation 1976; 53 (4): 627–32.

    PubMed  Google Scholar 

  3. Fisher LD, Judkins MP, Lesperance J, et al. Reproducibility of coronary angiographic reading in the coronary artery surgery study (CASS). Cathet Cardiovasc Diagn 1982; 8: 656–75.

    Google Scholar 

  4. Brown BG, Bolson E, Frimer F, Dodge HT. Quantitative coronary arteriography. Circulation 1977; 55; 329–37.

    PubMed  Google Scholar 

  5. Spears JR, Sandor T, Als AV, et al. Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms. Circulation 1983; 68: 453–61.

    PubMed  Google Scholar 

  6. Reiber JHC, Kooijman CJ, Slager CL, et al. Coronary artery dimensions from cineangiograms: methodology and validation of a computer-assisted analysis procedure. IEEE Trans Med Imag 1984; MI-3: 131–40.

    Google Scholar 

  7. Kirkeeide RL, Fung P, Smalling RW, Gould KL. Automated evaluation of vessel diameter from arteriograms. Comput Cardiol Proc IEEE 1982: 215.

  8. Mancini GBJ, Simon SB, McGillen MJ, LeFree MT, Freidman HZ, Vogel RA. Automated quantitative coronary arteriography: Morphologic and physiologic validation in vivo of a rapid digital angiographic method. Circulation 1987; 75: 452–60.

    PubMed  Google Scholar 

  9. Fujita H, Doi K, Pencil LE, Chua KG. Image feature analysis and computer-aided diagnosis in digital radiography. 2. Computerized determination of vessel sizes in digital subtraction angiography. Med Phys 1987; 14: 549–56.

    PubMed  Google Scholar 

  10. Fencil LE, Doi K, Hoffman KR. Accurate analysis of blood vessel sizes and stenotic lesions using stereoscopic DSA system. Invest Radiol 1988; 23: 33–41.

    PubMed  Google Scholar 

  11. Sander T, Als AV, Paulin S. Cine-densitometric measurement of coronary arterial stenosis. Cath Cardio Diag 1979; 5: 229–45.

    Google Scholar 

  12. Serruys PW, Reiber JHC, Wijns W, et al. Assessment of percutaneous transluminal coronary angioplasty: diameter versus densitometric area measurements. Am J Cardiol 1984; 54: 480–8.

    Google Scholar 

  13. Nichols AB, Gabrieli CFO, Fenoglio JJ, Esser PD. Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary angiograms. Circulation 1984; 69: 512–22.

    PubMed  Google Scholar 

  14. Tobis J, Nalcioglu O, Johnston WD, et al. Videodensitometric determination of minimum coronary artery luminal diameter before and after angioplasty. Am J Cardiol 1987; 59: 38–44.

    PubMed  Google Scholar 

  15. Kruger RA. Estimation of the diameter and the iodine concentration within blood vessels using digital radiography devices. Med Phys 1981; 8: 652–8.

    PubMed  Google Scholar 

  16. Molloi SY, Ersahin A, Roeck WW, Nalcioglu O. Absolute cross-sectional area measurement in quantitative coronary arteriography by dual-energy DA. Invest Radiol 1991; 26: 119–27.

    PubMed  Google Scholar 

  17. Molloi SY, Mistretta CA. Quantification techniques for dualenergy cardiac imaging. Med Phys 1989; 16: 209–17.

    PubMed  Google Scholar 

  18. Molloi SY, Weber DM, Peppter WW, Folts JD, Mistretta CA. Quantitative dual energy coronary arteriography. Invest Radiol 1990; 25: 908–14.

    PubMed  Google Scholar 

  19. Molloi SY, Mistretta CA. Scatter-glare corrections in quantitative dual-energy fluoroscopy. Med Phys 1988; 15: 289–97.

    PubMed  Google Scholar 

  20. Ersahin A. Instaneous brain blood flow measurements using first pass distribution analysis and digital subtraction angiography [Ph.D.]. University of Califomia-Irvine, 1993.

  21. Weber DM. Absolute diameter measurements of coronary arteries based on the first zero crossing of the Fourier spectrum. Med Phys 1989; 16: 188–96.

    PubMed  Google Scholar 

  22. Gewiritz H, Most A. Production of a critical coronary arterial stenosis in closed chest laboratory animals. Amer J Cardiol 1981; 47: 589–96.

    PubMed  Google Scholar 

  23. Gardiner GA, Meyerovitz MF, Boxt LM, et al. Selective coronary angiography using a power injector. AJR 1986; 146: 831–3.

    PubMed  Google Scholar 

  24. Bursch JH, Heintzen PH. Concepts for coronary flow and myocardial perfusion measurements. In: Heintzen PH, Bursch JH, (eds). Progress in digital angiocardiography. Dordrecht: Kluwer Academic Publishers, 1988: 201–13.

    Google Scholar 

  25. Hangiandreou NJ. Coronary blood flow measurement using digital subtraction angiography and first pass distribution analysis [Ph.D.]. University of Wisconsin-Madison, 1990.

  26. Brown BG, Bolson EL, Dodge HT. Quantitative computer techniques for analyzing coronary arteriograms. Prog Cariovasc Dis 1986; 28 (6): 403–18.

    Google Scholar 

  27. Thomas AC, Davies MJ, Dilly N, France F. Potential errors in the estimation of coronary arterial stenosis from clinical arteriography with reference to the shape of the coronary arterial lumen. Br Heart J 1986; 55: 129–39.

    PubMed  Google Scholar 

  28. Parker DL, Clayton PD, Gustafson DE. The effects of motion on quantitative vessel measurements. Med Phys 1985; 12 (6): 698–704.

    PubMed  Google Scholar 

  29. Van Der Zwet PMJ, Reiber JHC. A new approach for the quantification of complex lesion morphology: The gradient field transform; basic principles and validation results. JACC 1994; 24 (1): 216–24.

    PubMed  Google Scholar 

  30. Nalcioglu O, Roeck WW, Seibert JA, Lando AV, Tobis JM, Henry WL. Quantitative aspects of image intensifier-television based digital X-ray imaging. In: Kereiakes J, Thomas SR, Orton EG, (eds). Digital radiography: selected topics. New York: Plenum, 1986: 83–132.

    Google Scholar 

  31. Honda M, Ema T, Kikuchi M, One M, Komatsu K. A technique of scatter-glare correction using digital filtration. Med Phys 1993; 20: 59–69.

    PubMed  Google Scholar 

  32. Chackraborty DP. Image intensifier distortion correction. Med Phys 1987; 14: 249–52.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Molloi, S., Ersahin, A., Hicks, J. et al. In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography. Int J Cardiac Imag 11, 223–231 (1995). https://doi.org/10.1007/BF01145190

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01145190

Key words

Navigation