Skip to main content
Log in

The calculation of linear dimension and image area using a digitising tablet and personal computer

  • Published:
International journal of clinical monitoring and computing

Abstract

An inexpensive image-area and perimeter-length measurement system consisting of a personal computer and digital graphics tablet is described. A study to assess the efficacy of the system has shown that accuracy and reproducibility of area measurement increase with increasing size of cross-sectional area. The system generally underestimated all derived areas by less than 2%. Reproducibility of measurement, as defined by the coefficient of variation, was typically less than 2%; the greatest inaccuracies and variability occurring with shapes of smaller cross-sectional area. The system seems to be the least accurate when it measures shapes with rectangular symmetry. Neither direction of digitisation nor operator skill seemed to influence the measurement accuracy of the system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ramsey B, Lawrence CM. Measurement of Involved surface area in patients with psoriasis. Br J Dermatol 1991; 124: 565–70.

    Article  Google Scholar 

  2. Godfrey KA, Flanagan GJ, Gerrard J, Lind T. A Microcomputer Measuring System applied to Real-Time Ultrasound Video Imaging. J Clin Ultrasound 1981 9: 309–13.

    Article  PubMed  CAS  Google Scholar 

  3. Criscuolo GR, Oldfield EH. Measurement of Intracranial Tissue Volume using Computed Tomographic Images and a Personal computer. Neurosurgery 1988; 23: 671–4.

    Article  PubMed  CAS  Google Scholar 

  4. Gowlands Hopkins NF, Jamiesob CW. Antibiotic concentration in the exudate of venous ulcers: the prediction of ulcer healing rate. Br J Surg 1983; 70: 532–4.

    Article  Google Scholar 

  5. Bahmer FA. Measurement and figure in dermatology. Arch Dermatol 1986; 122: 501.

    Article  PubMed  CAS  Google Scholar 

  6. Bulstrode CJK, Goode AW, Scott PJ. Stereophotogammetry for measuring rates of cutaneous healing: a comparison with conventional techniques. Clin Sci 1986; 71: 437–43.

    PubMed  CAS  Google Scholar 

  7. Hook GR, Rasband W. MacMeasure: A low cost, easy-to-operate quantitative morphometrics system. In: Bailey GW (ed.)Proceedings of the 45th Annual Meeting of the Electron Microscopy Society, 1987: 920–1.

  8. Levell NJ, Lawrence CM. The use of a digitizer to measure are in dermatology. Physiol Meas 1993; 14: 401–10.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Taylor, R.J. The calculation of linear dimension and image area using a digitising tablet and personal computer. J Clin Monit Comput 12, 25–31 (1995). https://doi.org/10.1007/BF01142443

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01142443

Key words

Navigation