Summary
23 normal subjects were submitted to light, moderate and heavy work, performed in a continuous noise (80–110 dB). The study was divided into two parts: the first one was accomplished on the bicycle ergometer in the laboratory (300 or 450 kpm/min; 750 kpm/min and maximum load); the second part was carried out in the factory during the daily work. Each subject was studied both in a noisy atmosphere and in a sound-proofroom. Heart rate, systolic blood pressure, oxygen intake, ventilation, respiratory equivalent for oxygen and respiratory quotient were measured at each intensity of effort as well in the laboratory as in the factory. No significant differences were found for those parameters registered in noise or not.
Résumé
Nous avons étudié 23 sujets normaux au cours d'efforts d'intensité légère à très lourde, effectués dans un bruit continu de 80 à 110 dB. L'etude a été divisée en deux parties: la première a été accomplie au laboratoire sur la bicyclette ergométrique (300 ou 450Kgm/mm; 750Kgm/min et charge maximale), la deuxième a été faite au cours du travail journalier en milieu industriel. Chaque sujet a été étudié à la fois en milieu bruyant et non bruyant. La fréquence cardiaque, la pression artérielle systolique, la consommation d'oxygène, la ventilation, l'équivalent respiratoire pour l'oxygène et le quotient respiratoire ont été mesurés pour chaque intensité d'effort au laboratoire et à l'usine. Pour aucune de ces grandeurs, nous n'avons trouvé de différences significatives entre les valeurs enregistrées en milieu bruyant et celles enregistrées en milieu non bruyant.
Similar content being viewed by others
Abbreviations
- Respiratoires \(\dot V_{\operatorname{o} _2 } \) :
-
Consommation d'oxygène
- Respiratoires \(\dot V_{\operatorname{o} _2 } \) :
-
Puissance aérobique
- Respiratoires \(\dot V_E \) :
-
Ventilation par minute
- Respiratoires \({\text{ER}}_{{\text{O}}_{\text{2}} }\) :
-
Equivalent respiratoire pour l'oxygène
- Respiratoires R:
-
Quotient respiratoire
- Circulatoires. E.C.G.:
-
Electrocardiogramme
- Circulatoires. fh :
-
Fréquence cardiaque
- Circulatoires. Pahs :
-
Pression artérielle humérale systolique
- Circulatoires. Pahd :
-
Pression artérielle humérale diastolique
- Circulatoires. fh :
-
max Fréquence cardiaque maximale
Bibliographie
Degré, S., Denolin, H.: Etude de l'aptitude physique par détermination de la fréquence cardiaque au cours de l'effort et pendant la période de récupération. Acta cardiol. (Brux.)20, 17 (1965).
—, Messin, R., Denolin, H.: Enregistrement à distance de la fréquence cardiaque et de l'électrocardiogramme. Quelques aspects techniques de la télémétrie. Acta cardiol. (Brux.)21, 588 (1966).
— — —,: Détermination de l'aptitude physique par les épreuves d'effort. Arch. belges Méd. soc.4, 250 (1967).
—, Rogowsky, M., Vandermoten, P., Messin, B., Denolin, R.: Etude pratique des postes de travail et critique des résultats. Int. Z. angew. Physiol.25, 168 (1968).
Denolin, H., Messin, R., Degré, S., Vandermoten, P., De Coster, A.: Adaptation cardio-circulatoire au cours de l'effort musculaire: aspects physiologiques et applications pratiques. Acta cardiol. (Brux.)21, 663 (1966).
— — — — —: Influence of age on the behaviour of normal subjects during exercise. Physical Activity and aging.In: Medicine and sport, Vol. 4, p. 309. Basel-New York: Karger 1970.
Heinecker, R.: Individuelle Unterschiede in der Reaktion von Kreislauf und Gasstoffwechsel auf dosierte Belastungen. Arch. Kreisl.-Forsch.30, l (1969).
Heyters, C., Coenraerts, J. P., Messin, R., Degré, S.: Etudes de quelques paramètres cardiovasculaires et respiratoires chez des étudiants en éducation physique. Rev. Ed. Phys.6, 1 (1966).
Kaufmann et al. (1963): Cité par Wisner.
Messin, R., Degré, S.: Respiratory gas analysis. Med. Thor.23, 339 (1966).
—, Denolin, H., Degré, S.: Etude d'un test simple d'aptitude à l'effort: la CT170. Arch. Mal. Coeur3, 305 (1966).
Quaas, M., Lohs, M., Geiler, W., Platzbecker, V.: Zum Einfluß von Lärm auf die Herzfrequenz und den O2-Verbrauch bei mittelschwerer physischer Belastung. Int. Z. angew. Physiol.27, 230 (1969).
Rogowsky, M.: Etudes des variations de concommation d'oxygène et de fréquence cardiaque à différents postes de travail dans une usine d'assemblage automobile en corrélation avec un test d'aptitude physique à l'effort (cyclergomètre). Arch. belges Méd. soc.1, 1 (1967).
Spitzer, H., Hettinger, T. H.: Tables donnant la dépense énergétique en calories pour le travail physique. Paris: Cahier du BTE 1966.
Tarrière, C., Rebiffe, R., Pettier, M.: Utilisation chez l'homme d'un télécompteur de fréquence cardiaque. Trav. Humain3, 239 (1964).
Vandermoten, P., Messin, H., Degré, S., Denolin, H.: Interpretation of blood pressure in ergometry.In: Physiological and Clinical Aspects on Rehabilitation. Symposium held in Cagliari, June 1968. Mal. Cardiov.1–2, 207 (1970).
Wisner, A.: Audition et Bruit dans: Physiologie du travail. (Ergonomie) Tome II. Scherrer et al. Paris: Masson et Cie. 1967.
Author information
Authors and Affiliations
Additional information
Ce travail a été réalisé avec l'aide financière de la C.E.C.A.
Rights and permissions
About this article
Cite this article
Degré, S., Vandermoten, P., Messin, R. et al. Evolution de quelques grandeurs circulatoires, respiratoires et métaboliques au cours de l'effort physique accompli en milieu bruyant. Int. Z. Angew. Physiol. Einschl. Arbeitsphysiol. 29, 234–248 (1971). https://doi.org/10.1007/BF01100535
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01100535
Key-Words
- Physical Fitness
- Noise
- Heart Rate
- Oxygen Uptake
- Ventilation
- Blood Pressure
- Energy Expenditure during Daily Work