Summary
An adaptive algorithm for on-line kL-a estimation was developed. The accuracy of on-line kLa estimation was evaluated by means of digital and analog simulation. Simple difference schema developed on the basis of algorithm may be easily applicable in microcomputer-coupled fermentations.
Similar content being viewed by others
References
Fuchs, R., Ryu, D.Y., Humhrey, A.E. (1971). Ind. Eng. Chem., Process Des. Development 10, 190–196
Sobotka, M., and Votruba, J. (1980). Coll. Czech. Chem. Comm. 45, 2266–2271
Sobotka, M., Votruba, J., Krumphanzl, V., and Hradec, V. (1982). Kvasný prümysl (in Czech) 28, 87–89
Sobotka M., Prokop, A., Dunn, I.J., and Einsele, A. (1982). Review of methods for the measurement of oxygen transfer in microbial systems. In: Annual Review on Fermentation Processes, Vol. 5, pp. 127–210, Academic Press, N.Y.
Yoshida, T., Okaza, T. and Taguchi, H. (1980). Biotechnol. Bioeng. 22, 201–210
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Votruba, J., Guthke, R. On line estimation of a fermenter aeration capacity (kLa) by a computer and dissolved oxygen probe. Biotechnol Lett 7, 267–272 (1985). https://doi.org/10.1007/BF01042375