Fire drainage system

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

Present firesafety measures were conceived to deal with hypothetical fires spreading by destruction of successive compartment boundaries. A new firesafety system, referred to as the “fire drainage system,” is designed to cope with real-world fires spreading mainly by convection. It confines fire and smoke to the room of origin and to a small corridor element adjacent to the room. The system can be designed to operate without the use of water and electric energy. The fundamentals of its design are described and some experimental information is presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Yokoi, S., “A Method of Determining the Size of Vents”,Building Engineering Vol. 95, pp. 46–52, 1959. Translation by National Research Council of Canada, Division of Building Research, TT 884, Ottawa, 1960.

    Google Scholar 

  2. Thomas, P. H., Simms, D. L., Hinkley, P. L., and Theobald, C. R., “Roof Venting of Burning Enclosures, Part III. Venting Fires of Constant Heat Output,” JFRO, Fire Research Note No. 419, 1960.

  3. Landon-Thomas, G. J., and Hinkley, P. L., “Fire Venting in Single-Storey Buildings,” JFRO, Fire Note No. 5, HMSO, London, 1965.

    Google Scholar 

  4. Guide for Smoke and Heat Venting, National Fire Protection Association, Quincy, MA, No. 204M-1982.

  5. Tamura, G. T., and Wilson, A. G., “Pressure Differences for a Nine-Storey Building as a Result of Chimney Effect and Ventilation System Operation,” ASHRAE Trans., Vol. 72, Part I, pp. 180–189, 1966.

    Google Scholar 

  6. Tamura, G. T., and Wilson, A. G., “Pressure Differences Caused by Chimney Effect in Three High Buildings,” and “Building Pressures Caused by Chimney Action and Mechanical Ventilation,” ASHRAE Trans., Vol. 73, Part II, 1967.

  7. Harmathy, T. Z., “Design of Buildings for Fire Safety,”Fire Technology Vol. 12, p. 95, p. 219, 1976.

    Google Scholar 

  8. Harmathy, T. Z., “A New Look at Compartment Fires,”Fire Technology Vol. 8, p. 196, p. 326, 1972.

    Google Scholar 

  9. Harmathy, T. Z., “Some Overlooked Aspects of the Severity of Compartment Fires,”Fire Safety Journal Vol. 3, p. 261, 1981.

    Google Scholar 

  10. Streeter, V. L., and Wylie, E. B.,Fluid Mechanics McGraw-Hill Ryerson, Toronto, 1981, p. 237.

    Google Scholar 

  11. Harmathy, T. Z., “Means for Retarding the Spread of Fire from a Building Space,” U.S. Patent 3,955,323 (June 4, 1975), Can. Patent 1,009,889 (May 10, 1977).

  12. Pettersson, O., Magnusson, S. E., and Thor, J., “Fire Engineering Design of Steel Structures,” Swedish Institute of Steel Construction, Stockholm, Bulletin 50, 1976.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Reference: T. Z. Harmathy and I. Oleszkiewicz, “Fire Drainage System,”Fire Technology, Vol. 23, No. 1, February 1987, p. 26.

This paper is a contribution from the Institute for Research in Construction, National Research Council of Canada.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Harmathy, T.Z., Oleszkiewicz, I. Fire drainage system. Fire Technol 23, 26–48 (1987). https://doi.org/10.1007/BF01038364

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01038364

Key words

Navigation