Skip to main content
Log in

EMG muscle scanning: Stability of hand-held surface electrodes

  • Published:
Biofeedback and Self-regulation Aims and scope Submit manuscript

Abstract

Electromyographic (EMG) muscle scanning measures 2-second samples of integrated muscle action potentials from individual neck and back muscles using a hand-held scanner with post-style surface electrodes separated by a fixed distance. This “scanning” technique is widely used to expeditiously assess muscle activity in the diagnosis of musculoskeletal disorders. In order to determine if the 2-second sample is sufficiently representative of electrical activity at a specific muscle site, the stability of the signal received by the hand-held scanner was measured bilaterally at six neck and back muscle sites over 40 seconds (20 2-second integration periods) in five seated subjects. Taking the overall average EMG activity as the “true” value, the mean number of 2-second integration periods required to achieve <5% standard error was calculated to be 1.47 for the 60 muscles tested. Only three sites required more than five integration periods. The validity of EMG scanning as a diagnostic tool is enhanced by longer integration periods

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cram, J. R., & Engstrom, D. (1986). Patterns of neuromuscular activity in pain and non-pain patients.Clinical Biofeedback and Health, 9 106–115.

    Google Scholar 

  • Cram, J. R., & Steger, J. C. (1983). EMG scanning in the diagnosis of chronic pain.Biofeedback and Self-Regulation, 8 229–241.

    Google Scholar 

  • Ng, L. K. Y. (Ed.). (1983).New approaches to treatment of chronic pain: Review of Multidisciplinary pain centers. National Institute of Drug Abuse Research Monograph Series No. 36. Rockville, MD: Department of Health and Human Services.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thompson, J.M., Erickson, R.P. & Offord, K.P. EMG muscle scanning: Stability of hand-held surface electrodes. Biofeedback and Self-Regulation 14, 55–62 (1989). https://doi.org/10.1007/BF00999340

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00999340

Descriptor Key Words

Navigation