Use of contactless vacuum thermal transducers in pressure measurements

  • Published:
Measurement Techniques Aims and scope

Conclusions

Investigations showed that the TVB-6 transducer can be used with standard measuring equipment (ÉPP-09, numerical voltmeters, etc.) in measuring absolute pressures of 1.33–1330 Pa. The relative mean square error of the transducer is 5%. Its service life is 100 h. The transducer, which is made commercially, is compact and cheap. However, it requires a highly stable feed current and its characteristic is nonlinear.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature cited

  1. Catalogue of the Moscow Electric Lamp Plant, 1959, TU No. SUO.339.007.

  2. L. P. Khavkin, Zh. Tekh., Fiz., 25, No. 4 (1955).

  3. B. S. Danilin, Izmeritel'., Tekh., No. 1 (1957).

  4. A. M. Grigor'ev, L. P. Khavkin, and N. V. Tsybina, Pribory i Tekh. Eksperim. No. 3 (1958).

Download references

Authors

Additional information

Translated from Izmeritel'naya Tekhnika, No. 12, pp. 42–43, December, 1971.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Baldin, É.G., Burov, Y.V. & Maskaev, V.K. Use of contactless vacuum thermal transducers in pressure measurements. Meas Tech 14, 1848–1850 (1971). https://doi.org/10.1007/BF00994947