Conclusions
The method worked out here for the computation of the profile of a slit opening in variable level flow rate meters has been verified under actual industrial conditions and is recommended for the development of new designs of slit-type mass flow rate meters.
Similar content being viewed by others
Literature cited
Ya. T. Dub and V. L. Shkurienko, Izmeritel'. Tekh., No. 1 (1964).
P. P. Kremlevskii, Flow Rate Meters [in Russian], Mashgiz, Moscow-Leningrad (1963).
Yu. I. Vinogradov, “Investigation and development of schemes, measurement means, and automation means for systems for collecting and transporting petroleum and gas in trade,” Account on Subject 13–67 [in Russian], Giprovostokneft', Kuibyshev (1967).
Additional information
Translated from Izmeritel'naya Tekhnika, No. 2, pp. 53–55, February, 1971.
Rights and permissions
About this article
Cite this article
Korobov, A.P., Vinogradov, Y.I. & Akimov, V.F. Design of the profile of a proportional slit for variable level flow rate meters. Meas Tech 14, 259–261 (1971). https://doi.org/10.1007/BF00994696
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00994696