Summary
Both the theoretical and experimental data show that it is possible to apply the above technique in a general case for calculating, without the necessity of testing, the temperature characteristic of a strain gauge glued to any material providing it is supplied with a certificate indicating in the given temperature range the properties of the wire (α R,β 1) and of the wire network (S, R). Such a condition will exist if the manufacture of strain gauges with differing characteristics is centralized.
Similar content being viewed by others
Rights and permissions
About this article
Cite this article
Modlin, D.L. Method for computing temperature characteristic of a wire-wound strain gauge. Meas Tech 5, 842–846 (1962). https://doi.org/10.1007/BF00986531
Issue Date:
DOI: https://doi.org/10.1007/BF00986531