Conclusions
The slide rule with a special cursor can be used for computing errors in tested instruments of classes 0.5, 1 and 1.5, and for evaluating tolerances in tested instruments by means of pressure differences.
Similar content being viewed by others
Literature cited
A. S. Nemirovskii and S. M. Kessel'man, Izmerit. tekh., No. 9 (1963).
Procedure specification No. 192 on “Testing differential-manometer flowmeters made according to GOST 3720-60.” Standartgiz (State Standards Press), M., (1963).
Rights and permissions
About this article
Cite this article
Kessel'man, S.M. Slide rule with a special cursor for evaluating the basic error of differential-manometer flowmeters made according to GOST 3720-60. Meas Tech 7, 1097–1100 (1964). https://doi.org/10.1007/BF00983175