Measurement Techniques

, Volume 13, Issue 11, pp 1659–1662 | Cite as

Automatic check of the divisions of line-graduated gauges up to 1 m long

  • P. P. Alekseev
  • L. K. Kayak
  • N. V. Trishin
  • O. V. Yachmentsev
Linear and Angular Measurements
  • 10 Downloads

Conclusions

The value of the measurement error obtained experimentally agrees with the calculated error. Investigations of the FÉK-1000 confirmed the correctness of the selected measurement method and showed that this comparator is suitable for checking standard line-graduated gauges of the first rank and those of class 0, 1, and 2.

The use of the FÉK-1000 comparator for checking line-graduated gauges reduces the measurement error almost threefold and increases the productivity of checking fivefold in comparison with comparators based on the visual measurement method.

Keywords

Physical Chemistry Analytical Chemistry Measurement Error Measurement Method Visual Measurement 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literature cited

  1. 1.
    L. K. Kayak, N. V. Trishin, and O. V. Yachmentsev, Tr. VNIIM, No. 101(151) (1968).Google Scholar
  2. 2.
    N. V. Trishin, Tr. VNIIM, No. 78(138) (1965).Google Scholar
  3. 3.
    N. V. Trishin, Tr. VNIIM, No. 101(151) (1968).Google Scholar

Copyright information

© Consultants Bureau 1971

Authors and Affiliations

  • P. P. Alekseev
  • L. K. Kayak
  • N. V. Trishin
  • O. V. Yachmentsev

There are no affiliations available