Abstract

The adoption of the international temperature scale of 1990 (ITS-90) is producing significant innovation in thermal metrology. The temperature range of the ITS is wider than that of the previous editions. Also the scale precision and the accuracy of the thermodynamic temperature values forming its base have been improved. A short presentation of the ITS-90 will introduce its most important features, describing briefly the types of interpolating instruments and fixed points. To realize the ITS-90, many national laboratories will have to develop within their premises relatively new techniques of measurement such as gas thermometry to interpolate between fixed points from 3 K and 24.6 K and high-temperature platinum resistance thermometry. The highest precision is acheived in the temperature range −40°C to 30° C, where the ITS-90 combines the most reproducible fixed points with the interpolating instrument exhibiting the highest accuracy and the lowest nonuniqueness. Since a reproducibility better than 0.2 mK can be achieved everywhere in that range, except in the proximity of the triple point of water where it is lower than 0.1 mK (all estimates being at the 1σ level), the size of the kelvin is reporoduced to within 7·10−6 in the worst case, and to within 2·10−7 at the triple point of water. Some practical problems may result from the dissemination of the iTS-90 to users of temperature measurements in the temperature range 420–1085°C. They are related to the construction and use of high-temperature platinum resistance thermometers (HTPRTs), to the practical exploitation of radiation thermometry, and to the availabiality of suitable transfer standards in this temperature range. Several practical realizations of the ITS-90 that are underway in various national laboratories will enable one to better estimate its precision. Such an operation will essentially be carried out through intercomparisons, which will be successful if highly-reproducible transfer standards like the sealed cells for fixed points will be made available. The basic level of the scale precision, i.e., its irreducible component, is given by the scale nonuniqueness. Some results are already available and some experiments have recently been proposed in order to provide further data in critical areas. Another important aspect is the scale smoothness and its effect on the measured thermal properties. With the introduction of the ITS-90 the projects for the determination of thermodynamic properties have not completely stopped. Radiometric determinations and noise thermometry are mainly carried out at temperatures between 660°C and 1085°C. Other experiments involving gas thermomery may lead to better determinations below 3 K. Thermal noise measurements are presently considered for the redetermination of the Boltzmann constant, kB. Their uncertainty should be within ± 10ppm, still too high to propose such a method for the definition of the kelvin in terms of kB and of the SI unit of energy. As regards the determination of thermophysical properties of matter, special importance is now attributed to the temperature dependence of the vapor pressure of sodium. Such an interest in connection with the use of pressure-controlled sodium heat pipes for temperature reference. In addition, some information is provided on methods for the determination of pulsed-energy excitation. There, advantage is taken from improvements in radiation thermometry.

Keywords

Heat Pipe Irreducible Component Triple Point Platinum Resistance Thermometer Transfer Standard 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    H. Preston-Thomas,Metrologia 27, 3–10, 107 (1990).Google Scholar
  2. 2.
    H. Preston-Thomas, P. Bloembergėn, and T. J. Quinn,Supplementary Information for the International Temperature Scale of 1990, Bureau International des Poids et Mesures (BIPM), F-92310 Sévres (1990).Google Scholar
  3. 3.
    H. Preston-Thomas, T. J. Quinn, and R. P. Hudson,Metrologia 21, 75–79 (1985).Google Scholar
  4. 4.
    R. L. Rusby, R. P. Hudson, M. Durieux, J. F. Schooley, P. P. M. Steur, and C. A. Swenson,Metrologiya 28, 9–18 (1991).Google Scholar
  5. 5.
    L. Crovini, H. J. Jung, R. C. Kemp, S. K. Ling, B. W. Mangum, and H. Sakurai,Metrologia 28, 317–325 (1991).Google Scholar
  6. 6.
    G. F. Stouse, “IST assessment of the ITS-90 non-uniqueness for 25.5 Ω SPRTs at gallium, indium, and cadmium fixed points,” in:Temperature: Its measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press.Google Scholar
  7. 7.
    G. F. Strouse, “Investigation of the ITS-90 sub-range inconsistency for 25.5 Ω SPRTs,”ibid. in: (1992).Google Scholar
  8. 8.
    L. Covini, and P. Marcarino, High-Temp.-High Pressures23 (1991), in press.Google Scholar
  9. 9.
    P. Marcarino, and C. Bassani, “Approximation of the ITS-90 between 660°C and 962°C using the sodium vapor P-T relation,” in:Temperature: Its Measurement and Control in Science and industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press.Google Scholar
  10. 10.
    P. P. M. Steur, and F. Pavese, “3He Gas Thermometry at IMGC,”ibid. in: (1992).Google Scholar
  11. 11.
    R. L. Rusby, “The rhodium-iron resistance thermometer, ten year on, “ in:Temperature, Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 5, American Institute of Physics, New York (1982), pp. 829–833.Google Scholar
  12. 12.
    R. E. Bedford, G. Bonnier, H. Maas, and F. Pavese,Techniques for Approximating the International Temperature Scale of 1990, BIPM, F-92310 Sévres (1990).Google Scholar
  13. 13.
    G. C. Bussolino, F. Righini, and A. Rosso, “Transfer-standard pyrometer above 1000 K at IMGC,” in:Temperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, new York (1991), in press.Google Scholar
  14. 14.
    F. Sakuma and S. Hattori, “Establishing a practical temperature standard by using a narrow-band radiation thermomter with a silicon detector,” in:Temperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 5, American Institute of Physics, New York (1982), pp. 421–427.Google Scholar
  15. 15.
    G. W. Burns, et al., “New reference function for platinum-10% rhodium versus platinum (type S) thermocouples based on the ITS-90. Part I: Experimental procedures; Part II: results and discussions,” in:Temperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press. See also: G. W. Burns, et al., “New reference functions for platinum-13% rhodium versus platinum (type R) and platinum-30% rhodium versus platinum-6% rhodium (type B) thermocouples based on the ITS-9-,”ibid.Google Scholar
  16. 16.
    M. Battuello, F. Lanza, and T. Ricolfi,Metrologia 27, 75–82 (1990).Google Scholar
  17. 17.
    B. W. Mangum, and G. T. Furukawa,Guidelines for Realizing the International Temperature scale of 1990 (ITS-90) NIST Technical Note 1265, U. S. Department of Commerce, NIST, Gaithersburgh, MD (1990).Google Scholar
  18. 18.
    F. Pavese, and P. P. M. Steur, “Implementation of the International Temperature Scale of 1990 below 273.16 K at IMGC,” in:Temperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press.Google Scholar
  19. 19.
    P. Marcarino, et al., “An inter laboratory comparison of tin and zinc fixed points,”ibid. in: (1992).Google Scholar
  20. 20.
    H. J. Jung, PTB-Mitteilungen,99, 351–356 (1989).Google Scholar
  21. 21.
    G. F. Strouse, “NIST implementation and realization of the ITS-90 over the range 83 K to 1253 K: reproducibility, stability, and uncertainties,” in:Temperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press. See also: G. F. Strouse, B. W. Mangum, A. I. Polhodun, and N. P. Moiseeva, “Investigation of high-temperature resistance thermometers at temperatures up to 962°C, and, in some ases, 1064°C,”ibid. (1992).Google Scholar
  22. 22.
    L. Crovini, in:Metrology at the frontiers of Physics and Technology, L. Crovini and T. J. Quinn (ed.), North Holland (Amsterdam) (1992), pp. 297–327, in press.Google Scholar
  23. 23.
    N. P. Fox, J. E. Martin, and D. H. Nettleton,Metrologia 28, 221–227 (1991).Google Scholar
  24. 24.
    J. Fischer, Fu Lei, and M. Stock,Metrologia 28, 243–246 (1991).Google Scholar
  25. 25.
    L. Crovini, A. Actis, and R. Galleano, “Noise thermometry in the temperature range 1235 K to 1357 K,” in:Teperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press.Google Scholar
  26. 26.
    L. Storm,Metrologia 22, 229–234 (1986).Google Scholar
  27. 27.
    M. Tischler, and W. Nubert. “Miniature thermometric fixed-points, calibration of a pressure-controlled heat-pipe furnace, and the vapor pressure of Na (660°C to 1064°C). Part II: Results and conclusions,” in:Temperature: Its Measurement and Control in Science and Industry, J. F. Schooley (ed.), Vol. 6, American institute of Physics, New York (1992), in press.Google Scholar
  28. 28.
    International Union of Pure and Applied Chemistry,Recommended Reference Materials for the Realization of Physicochemical Properties, K. N. March (ed.), Blackwell Scientific Publications, oxford U. K. (1987).Google Scholar
  29. 29.
    F. Righini, G. C. Bussolino, and A. Rosso, “Subsecond Measurements of Thermophysical Properties (1000–4000 K),” in:Proceedings of Conference Temperature 92, Dusseldorf, October 1992, VDI Berichtn. 892, VDI-Verlag, Dusseldorf (1992).Google Scholar
  30. 30.
    A. Cezairliyan, A. P. Miller, F. Righini, and A. Rosso, “Radiance temperature and normal spectral emissivity of metals at their melting point as possible reference values,” in:Temperature: Its Measurement and Control in Science and Industry,” J. F. Schooley (ed.), Vol. 6, American Institute of Physics, New York (1992), in press.Google Scholar

Copyright information

© Plenum Publishing Corporation 1994

Authors and Affiliations

  • Luigi Crovini
    • 1
  1. 1.Instituto di Metrologia “G. Colonnetti” - CNRTurinItalia

Personalised recommendations