Conclusions
-
1.
The values of the initial coefficients of discharge for double-bevel diaphragms were determined for moduli of 0.0905, 0.1624, 0.2504 and 0.3694 in the Re range of 240 to 1900.
-
2.
The root-mean-square error of the initial discharge coefficient did not exceed 0.18%.
-
3.
The relation ofα u=f(m; Re) derived in the article makes the calculation of double-bevel diaphragms possible for Re values between 240 and 1900.
Similar content being viewed by others
Literature cited
Rules 27–54 on the use and checking of flowmeters with normal diaphragms, nozzles and Venturi tubes [in Russian] (Mashgiz, 1955).
VDI- Durchfluβ-Meβregeln DIN 1952, 6 Auflage, (1948).
R. Witte, VDI-Zeitschrift,87, No. 18/20 (1943).
L. Ferroglio, L'Energia Elettrica,19, 413 (1942).
C. Schmid and K. Schneider, Erdöl and Kohle, No. 6 (1948).
A. Schlag, Revue Universelle des Mines, No. 2 (1950).
V. I. Romanenko, Hydrolysis and the Wood-Chemical Industry, No. 1, (1958).
Rights and permissions
About this article
Cite this article
Romanenko, V.I. Discharge coefficients of double bevel diaphragms. Meas Tech 3, 237–241 (1960). https://doi.org/10.1007/BF00975956