Radiocirculography in congenital heart disease in children with intracardiac shunts

  • Originals
  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

A modification of radiocirculography suitable for the investigation of children suffering from congenital heart disease was developed and tested in 55 children with intracardiac shunts. Comparison of data derived from radiocirculography with the data obtained by conventional cardiac catheterisation showed radiocirculography has a high degree of accuracy when it is used to assess shunt size. Pulmonary arterial and capillary pressures and pulmonary resistance values were derived from radiocirculography findings and compared with those obtained from catheterisation studies: only in children of school age could the two be closely correlated. In cyanotic heart disease morphological analysis of the radiocirculographic curves proved an especially helpful diagnostic aid. The close agreement between the assessment of aortic override when using angiography and radiocirculography was demonstrated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Di Matteo, J., Picard, R., Vacheron, A., Kellershohn, C., Vernejoul, P. de: Étude hémodynamique des cardiopathies valvulaires aortiques par la dilution isotopiques. Arch. Mal. Cœur,60, 1061–85 (1967).

    Google Scholar 

  2. Di Matteo, J., Picard, R., Kellershohn, C., Vernejoul, P. de: Détermination des volumes et des indices d'éjection ventriculaire par la radiocardiographie. Application à l'étude du cœur thyréoidien. Arch. Mal. Cœur,59, 57–71 (1966).

    Google Scholar 

  3. Di Matteo, J., Picard, R., Vacheron, A., Bousquet, O., Kellershohn, C., Vernejoul, P. de: Mésure du volume sanguin central circulant et des temps de traversée pulmonaire par la radiocardiographie dans les shunts gauchedroite. Arch. Mal. Cœur,62, 160–72 (1969).

    Google Scholar 

  4. Di Matteo, J., Picard, R., Vacheron, A., Kellershohn, C., Vernejoul, P. de: Intéret des courbes de dilution isotopiques dans les cardiopathies à shunt droite-gauche. Soc. Méd. Hósp. de Paris,119, 275–82 (1968).

    Google Scholar 

  5. Guintini, C.: Theoretical considerations on the mesure of Pulmonary blood volume and extravascular lung water. Bull. Physio-path. Respir. 7 (1971).

  6. Ivančevič, D., Vernejoul, P. de, Kellershohn, C.: Radiocirculografic determination of systemic and pulmonary flow in atrial septal defect. Proc. of the 1st Internat. Symp. on Nucl. Med. 67–74. Ed. O. Andrýsek, J. Měštan, Charles University Prague, 1970.

  7. Pietila, K. A., Hakkila, J.: Studies of cardiac output and of pulmonary and intrathoracic blood volume. Cardiologia 36/2 (1960).

    Google Scholar 

  8. Vernejoul, P. de, Delaloy, B., Di Gregorio, V., Kellershohn, C.: Mésure du débit cardiaque et des volumes ventriculaires par radiocardiographie. Rev. franç. Étud. clin. et biol.9, 693–715 (1964).

    Google Scholar 

  9. Vernejoul, P. de, Delaloy, B., Měštân, J.: Application de la radiocardiographie à mésure des pressions et des resistances pulmonaires. Proc. of the 1st Internat. Symp. on Nucl. Med., 59–66. Ed. O. Andrýsek, J. Měšťan, Charles University Prague, 1970.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hrubá, B., Šamánek, M. & Tûma, S. Radiocirculography in congenital heart disease in children with intracardiac shunts. Pediatr Radiol 1, 47–52 (1973). https://doi.org/10.1007/BF00972824

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00972824

Key words

Navigation