Über die Zulässigkeit der Subtraktion der Lösungsmittelstreuung von der Streuung der Lösungen bei Röntgenkleinwinkelstreuungsmessungen

On the validity of subtracting solvent contributions from the scattering of solutions in small-angle X-ray measurements

  • Published:
Monatshefte für Chemie / Chemical Monthly Aims and scope Submit manuscript

Abstract

The approximation of subtracting solvent scattering intensity from solution scattering intensity to obtain the scattering of solute particles is examined in detail for several models. It is found that angularly dependent terms dependent on the solvent structure appear in the intensity difference if the solvent exhibits spatially correlated electron density fluctuations. The nature of these terms is examined.

Zusammenfassung

Die Näherungsmethode, die Lösungsmittelstreuung von der Streuung der Lösung abzuziehen, um so die Streuung der gelösten Partikel zu erhalten, wird für mehrere Modelle im Detail geprüft. Es stellt sich heraus, daß von der Lösungsmittelstruktur herrührende winkelabhängige Terme in der Intensitätsdifferenz aufscheinen, wenn das Lösungsmittel räumlich korrelierte Dichtefluktuationen zeigt. Diese Terme werden auf ihr Verhalten hin untersucht.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. O. Kratky, Progr. in Biophys.13, 105 (1963).

    Google Scholar 

  2. Siehe z. B.J. W. Anderegg, W. W. Beeman, S. Shulman undP. Kaesberg, J. Amer. Chem. Soc.77, 2927 (1955).

    Google Scholar 

  3. O. Kratky undW. Worthmann, Mh. Chem.76, 263 (1947).

    Google Scholar 

  4. O. Kratky, G. Porod undA. Sekora, ibid.78, 295 (1948).

    Google Scholar 

  5. O. Kratky undG. Porod, Rec. Trav. Chim. Pays-Bas68, 1106 (1949).

    Google Scholar 

  6. G. Porod, Kolloid-Z.124, 83 (1951).

    Google Scholar 

  7. R. G. Kirste undW. Wunderlich, Makromol. Chem.87, 60 (1965).

    Google Scholar 

  8. A. Guinier, X-Ray Diffraction, Kap. 2. San Francisco:W. H. Freeman and Co. 1963.

    Google Scholar 

  9. A. Guinier, G. Fournet, C. B. Walker undK. L. Yudowitch, Small-Angle Scattering of X-Rays. New York: Wiley. 1955.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof.O. Kratky anläßlich seines 70. Geburtstages gewidmet.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Goodisman, J., Brumberger, H. Über die Zulässigkeit der Subtraktion der Lösungsmittelstreuung von der Streuung der Lösungen bei Röntgenkleinwinkelstreuungsmessungen. Monatshefte für Chemie 104, 598–606 (1973). https://doi.org/10.1007/BF00903127

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00903127

Navigation