Skip to main content
Log in

Tests of a robust eddy correlation system for sensible heat flux

  • Published:
Theoretical and Applied Climatology Aims and scope Submit manuscript

Summary

Sensible heat flux estimates from a simple, one-propeller eddy correlation system (OPEC) were compared with those from a sonic anemometer eddy correlation system (SEC). In accordance with similarity theory, the performance of the OPEC system improved with increasing height of the sensor above the surface. Flux totals from the two systems at sites with adequate fetch were in excellent agreement after frequency response corrections were applied. The propeller system appears suitable for long periods of unattended measurement. The sensible heat flux measurements can be combined with net radiation and soil heat flux measurements to estimate latent heat as a residual in the surface energy balance.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Amiro, A., Wuschke, E. E., 1987: Evapotranspiration from a boreal forest drainage basin using an energy balance/eddy correlation technique.Bound.-Layer Meteor. 38, 125–139.

    Google Scholar 

  • Blanford, J. H., Stannard, D. I., 1991: Spatial variability of energy fluxes at Walnut Gulch. In:20th Conference on Agricultural and Forest Meteorology, Boston, MA: Amer. Meteor. Soc., 116–119.

    Google Scholar 

  • Businger, J. A., Miyake, M., Dyer, A. J., Bradley, E. F., 1967: On the direct determination of the turbulent heat flux near the ground.J. Appl. Meteor. 6, 1025–1031.

    Google Scholar 

  • Garratt, J. R., 1975: Limitations of the eddy-correlation technique for the determination of turbulent fluxes near the surface.Bound.-Layer Meteor. 8, 255–259.

    Google Scholar 

  • Hicks, B. B., 1972: Propeller anemometers as sensors of atmospheric turbulence.Bound.-Layer Meteor. 3, 214–228.

    Google Scholar 

  • Holmes, R. M., Gill, G. C., Carson, H. W., 1964: A propellertype vertical anemometer.J. Appl. Meteor. 3, 802–804.

    Google Scholar 

  • Horst, T. W., 1973: Corrections for response errors in a threecomponent propeller.J. Appl. Meteor. 12, 716–725.

    Google Scholar 

  • Kaimal, J. C., Wyngaard, J. C., Haugen, D. A., 1968: Deriving power spectra from a three-component sonic anemometer.J. Appl. Meteor. 7, 827–834.

    Google Scholar 

  • Kaimal, J. C., Wyngaard, J. C., Izumi, Y., Cote, O. R., 1972: Spectral characteristics of surface-layer turbulence.Quart. J. Roy. Meteor. Soc. 98, 563–589.

    Google Scholar 

  • Laughton, J. K., 1882: Historical sketch of anemometers and anemometry.Quart. J. Roy. Meteor. Soc. 8, 161–189.

    Google Scholar 

  • McBean, G. A., 1972: Instrument requirements for eddy correlation measurements.J. Appl. Meteor. 11, 1078–1084.

    Google Scholar 

  • McBean, G. A., Miyake, M., 1972: Turbulent transfer mechanisms in the atmospheric surface layer.Quart. J. Roy. Meteor. Soc. 98, 383–398.

    Google Scholar 

  • Miyake, M., Stewart, R. W., Burling, R. W., 1970: Spectra and cospectra of turbulence over water.Quart. J. Roy. Meteor. Soc. 96, 138–143.

    Google Scholar 

  • Moore, C. J., 1986: Frequency response corrections for eddy correlation systems.Bound.-Layer Meteor. 37, 17–35.

    Google Scholar 

  • Panofsky, H. A., Dutton, J. A., 1984:Atmospheric Turbulence. New York: John Wiley, 397 pp.

    Google Scholar 

  • Shaw, W. J., Tillman, J. E., 1980: The effect of and correction for different wet-bulb and dry-bulb responses in thermocouple psychrometry.J. Appl. Meteor. 19, 90–97.

    Google Scholar 

  • Spittlehouse, D. L., Black, T. A., 1979: Determination of forest evapotranspiration using Bowen ratio and eddy-correlation measurements.J. Appl. Meteor. 18, 647–653.

    Google Scholar 

  • Stull, R. B., 1988:An Introduction to Boundary Layer Meteorology. Dordrecht, The Netherlands: Kluwer Academic Publishers, 666 pp.

    Google Scholar 

  • Swinbank, W. C., 1951: The measurement of vertical transfer of heat and water vapor and momentum in the lower atmosphere.J. Meteor. 8, 135–145.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

With 6 Figures

Rights and permissions

Reprints and permissions

About this article

Cite this article

Blanford, J.H., Gay, L.W. Tests of a robust eddy correlation system for sensible heat flux. Theor Appl Climatol 46, 53–60 (1992). https://doi.org/10.1007/BF00866448

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00866448

Keywords

Navigation