Advertisement

Journal of engineering physics

, Volume 36, Issue 1, pp 110–113 | Cite as

Application of dimensional analysis to the problem of the action of ultrasound on air in a capillary tube

  • N. P. Migun
  • P. P. Prokhorenko
  • S. P. Fisenko
Article
  • 27 Downloads

Abstract

By using dimensional analysis an expression is obtained for the air pressure change in a capillary tube channel caused by the effect of ultrasound. A comparison with experimental results is performed.

Keywords

Statistical Physic Capillary Tube Dimensional Analysis Capillary Tube Channel Tube Channel 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literature cited

  1. 1.
    L. I. Sedov, Dimensional Analysis and Similarity in Mechanics [in Russian], Nauka, Moscow (1977).Google Scholar
  2. 2.
    N. P. Migun and P. P. Prokhorenko, Inzh.-Fiz. Zh.,34, No. 5 (1978).Google Scholar
  3. 3.
    G. Huntley, Dimensional Analysis [Russian translation], Mir, Moscow (1970).Google Scholar

Copyright information

© Plenum Publishing Corporation 1979

Authors and Affiliations

  • N. P. Migun
    • 1
    • 2
  • P. P. Prokhorenko
    • 1
    • 2
  • S. P. Fisenko
    • 1
    • 2
  1. 1.Physicotechnic InstituteUSSR
  2. 2.A. V. Lykov Institute of Heat and Mass TransferAcademy of Sciences of the Belorussian SSRMinsk

Personalised recommendations