Conclusions
-
1.
The difference in calculating the mean diameters according to [1] and from the suggested formula (1), with the new expression for the correction taken into consideration, amounts to 7μ.
-
2.
When the mean diameter of tapering thread plug gauges with an asymmetrical profile threaded according to GOST 9909-70 are measured by means of the three-cylinder method with the well-known angular attachment, it is recommended to use for calculation purposes the expressions (1) and (2) which provide more precise results.
Similar content being viewed by others
Literature cited
N. M. Borzka and A. M. Chernyak, Izmeritel'. Tekh., No. 3 (1956).
Additional information
Translated from Izmeritel'naya Tekhnika, No. 1, pp. 87–88, January, 1974.
Rights and permissions
About this article
Cite this article
Akhanyanova, L.V. Measuring the mean diameter of tapering thread gauges with an asymmetrical profile. Meas Tech 17, 143–144 (1974). https://doi.org/10.1007/BF00835029