Abstract
The objective of this study was to establish a probe system for intraoperative quantitative leakage measurement during selective limb perfusion for adjuvant high-dose chemotherapy in patients with malignant melanomas. We used a portable gamma probe with digital display and investigated the physical properties in a phantom study simulating blood pool activity at different angles of the probe to the surface and different distances. In 20 patients the limb circulation was surgically separated from the systemic blood circulation, and the limb was then selectively perfused (cytostatics added) for 60 min. Initially, 15 MBq technetium-99m labelled autologous red blood cells was injected into the limb circulation, and an equal amount was kept as a standard. Every 10 min, blood samples were drawn from the body circulation and count rates were simultaneously measured by the probe system at the lower end of the sternal body. At the end of perfusion, the circulation of the limb was reconnected, the standard injected into the systemic circulation, and a blood sample drawn after 10 min. All blood samples were counted for calculation of leakage in terms of percent of the injected dose, and the results compared with the intraoperative count rates of the probe system. In the range of leakage observed in this study (0%–86%), the count rate of the probe system (corrected for blood volume, i.e. for body surface) correlated with the results of conventional measurement (r=0.92) according to the equation: %leakage=counts per sx[1.2×body surface (m2)−1.19]. In conclusion, the use of the described probe system is a feasible approach for leakage quantification which continuously yields data during selective limb perfusion.
Similar content being viewed by others
References
Fletcher JR, White CR, Fletcher WS. Improved survival rates of patients with acral lentiginous melanoma treated with hyperthermie isolation perfusion, wide excision, and regional lymphadenectomy.Am J Surg 1986; 151: 593–598.
Krements ET, Carter RD, Sztherland CM, Muchmore JH. Chemotherapy by regional perfusion for limb melanoma.Am Surg 1987; 53: 133–140.
Ghussen F, Krueger I, Groth W, Stützer H. The role of regional hyperthermie cytostatic perfusion in the treatment of extremity melanoma.Cancer 1988; 61: 654–659.
Kroon BRB. Regional isolation perfusion in melanoma of the limbs; accomplishment, unsolved problems, future.Eur J Surg Oncol 1988; 14: 101–110.
Santinami M, Belli F, Cascinelli N, Rovini D, Vaglini M. Seven years' experience with hyperthermie perfusion in extracorporeal circulation for melanoma of the extremities.J Surg Oncol 1989; 42: 201–208.
Siddik ZH, Edwards MJ, Boddie AW. Isolated limb perfusion with chemotherapeutic agents for melanoma: a reevaluation of drug dosimetry.Eur J Cancer Clin Oncol 1989; 25: 1393–1397.
Coit DG. Hyperthermie isolation limb perfusion for malignant melanoma.Cancer Invest 1992; 10: 277–284.
Stehlin JS, Clark RL, White EC, Healy JE, Dewey WC, Beerstecher S. The leakage factor in regional perfusion with chemotherapeutic agents.Arch Surg 1960; 80: 934–945.
Hafstroem L, Hugander A, Joensson PE, Westling H, Ehrsson H. Blood leakage and melphalan leakage from the perfusion circuit during regional hyperthermie perfusion for malignant melanoma.Cancer Treat Rep 1984; 68: 867–872.
Krige JEJ, King HS, Strover RM. Prophylactic hyperthermie limb perfusion in stage I melanoma.Eur J Surg Oncol 1988; 14: 321–326.
Sardi A, Minton JP, Mojzisik C, Nieroda CA, Ferrara PJ, Hinkle GH, Thurston MO, Martin GH. The use of a hand-held gamma detector improves the safety of isolated limb perfusion.J Surg Oncol 1989; 41: 172–176.
Manner M, Sinn H, Bubeck H, Kettelhack C, Schlag P. Verbesserte intraoperative Leckkontrolle bei der isolierten Zytostatikaperfusion von Extremitätentumoren.Langenbecks Arch Chir 1990; 375: 208–213.
Alexander C, Omlor G, Berberich R, Gross G, Feifel G. Rapid measurement of blood leakage during regional chemotherapy.Eur J Nucl Med 1993; 20: 187–191.
Sprenger HJ, Markwardt J, Schlag PM. Quantitative Leckkontrolle mit Radionukliden bei der isolierten Extremitätenperfusion.Nucl Med 1994; 33: 248–253.
Hickernell TS, Barber HB, Barrett HH, Woolfenden JM. Dual-detector probe for surgical tumor staging.J Nucl Med 1988; 29: 1101–1106.
Adams S, Hovy L, Baum RP, Adams M, Maul FD, Kahla-Witzsch H, Zicher L, Jonas D, Hör G. Preoperative localization of metastases with a hand-held gamma-probe.Nucl Med 1995; 34: 161–164.
Kirchner B, Hillmann A, Lottes G, Sciuk J, Bartenstein P, Winkelmann W, Schober O. Intraoperative, probe-guide curettage of osteoid osteoma.Eur J Nucl Med 1993; 20: 609–613.
Ricard M, Tenenbaum F, Schlumberger M, Travagli JP, Lumbrosco J, Revillon Y, Parmentier C. Intraoperative detection of pheochromocytoma with iodine-125 labelled meta-iodobenzylguanidine: a feasibility study.Eur J Nucl Med 1993; 20:426–430.
Ciba-Geigy. Wissenschaftliche Tabellen Geigy, Teilband Hämatologie und Humangenetik, 8th edn. Basel: Ciba Geigy, 1979.
Wieberdink J, Benckhuysen C, Braat RP, Van Slooten EA, Olthuis GAA. Dosimetry in isolation perfusion of the limbs by assessment of perfused tissue volume and grading of toxic tissue reactions.Eur J Cancer Clin Oncol 1982; 18: 905–910.
Van Os J, Koops HS, Oldhoff J. Dosimetry of cytostatics in hyperthermic regional isolated perfusion.Cancer 1985; 55: 698–701.
Siddik ZH, Edwards MJ, Boddie AW. Isolated limb perfusion with chemotherapeutic agents for melanoma: a reevaluation of drug dosimetry.Eur J Cancer Clin Oncol 1989; 23: 1393–1397.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sandrock, D., Horst, F., Gatzemeier, W. et al. Leakage measurement during selective limb perfusion using a gamma probe. Eur J Nucl Med 23, 534–538 (1996). https://doi.org/10.1007/BF00833388
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00833388