Abstract
The gas-dynamic stability limits of electric-arc heaters have been experimentally investigated and the effect of the principal electrical, gas-dynamic and geometrical factors on arc stabilization is established. A design equation for calculating anode diameter is obtained such that steady vortex stabilization is ensured within the operating range of the heater.
Similar content being viewed by others
References
V. L. Sergeev, V. P. Trofimov, F. B. Yurevich, and O. I. Yas'ko, IFZh, no. 1, 1963.
G. Yu. Dautov, M. F. Zhukov, and V. Ya. Smolyakov, PMTF, no. 6, 1961.
I. K. Harvey, P. G. Simpkins, B. D. Adcock, AJAA, vol. 1, no. 3, 1963.
B. D. Voronin, B. V. Zolotov, M. Ya. Smelyanskii, A. M. Tsirlin, and V. P. Tsishevskii, Elektrotermiya, no. 5, 1963.
V. P. Tsishevskii, B. V. Zolotov, M. Ya. Smelyanskii, A. M. Tsirlin, and B. D. Voronin, Elektrotermiya, no. 11, 1963.
S. S. Kutateladze and O. I. Yas'ko, IFZh, no. 4, 1964.
Rights and permissions
About this article
Cite this article
Voronin, B.D., Tsirlin, A.M. & Smelyanskii, M.Y. Allowance for gas-dynamic factors in the design of electric-arc heaters with vortex gas stabilization. Journal of Engineering Physics 10, 169–172 (1966). https://doi.org/10.1007/BF00832617
Issue Date:
DOI: https://doi.org/10.1007/BF00832617