Cardiac single-photon emission tomography with a 90° dual-head system

  • Short Communication
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Dual-head single-photon emission tomography (SPET) systems which permit a 90° orientation of the heads provide a twofold increase in sensitivity for 180° SPET compared with single-head systems. Since such systems have additional mechanical and electrical alignment and stability requirements, clinical equivalency for myocardial perfusion SPET must be demonstrated. Accordingly, we studied 26 subjects who underwent exercise thallium scintigraphy consecutively with both single-head and dual-head systems. Image acquisition was similar, except that the dual-head study took one-half the time. Image reconstruction was identical. Images were interpreted in a blinded fashion, and rated for technical quality. All 26 studies were equivalently interpreted for the presence or absence of perfusion defects. Fourteen of the studies were judged to be technically equivalent; seven were judged to be slightly better with the single-head system; three were judged to be slightly better with the dual-head system; and two were judged to be definitely better with the dual-head system. We conclude that dual-head 90° systems provide equivalent clinical performance in half the acquisition time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Links JM. Multi-detector SPET.Eur J Nucl Med 1993; 20: 440–447

    Google Scholar 

  2. Geckle WJ, Frank TL, Links JM, Becker LC, Correction for patient and organ movement in SPECT: application to exercise thallium-201 cardiac imaging.J Nucl Med 29: 441–450

  3. Links JM, Jeremy RW, Frank T, Becker LC. Wiener filtering improves quantification of myocardial blood flow with thallium SPECT.J Nucl Med 1990; 31: 1230–1236.

    Google Scholar 

  4. Cauvin JC, Boire JY, Maublant JC, Bonny JM, Zanca M, Veyre A. Automatic detection of the left ventricular myocardium long axis and center in thallium-201 single photon emission computed tomography.Eur J Nucl Med 1992; 1032–1037.

  5. Fintel DJ, Links JM, Bringer JA, Frank TL, Parker M, Becker LC. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease — a receiver operating characteristic analyis.J Am Coll Cardiol 1989; 13: 600–612.

    Google Scholar 

  6. Eisner RL, Nowak DJ, Pettigrew R, Fajman W. Fundamentals of 180° acquisition and reconstruction in SPECT imaging.J Nucl Med 1986; 27: 1717–1728.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Links, J.M., Frank, T.L., Engdahl, J.C. et al. Cardiac single-photon emission tomography with a 90° dual-head system. Eur J Nucl Med 22, 548–552 (1995). https://doi.org/10.1007/BF00817280

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00817280

Key words

Navigation