Increased sensitivity through use of overlapping 180° orbits in clinical myocardial perfusion imaging

  • Short Communication
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Clinical cardiac imaging is hindered by noise due to limited activity and imaging time. Use of 90° dual-detector systems with 90° gantry rotation may provide the best sensitivity/resolution for cardiac imaging, but this option is not readily available to those using a triple-detector system with detectors at 120° intervals. This study utilizes a cardiac/chest phantom to compare several triple-detector orbits, with assessment of sensitivity and resolution. A 180° rotation with reconstruction of two of the three heads was evaluated, resulting in overlapping 180° orbits; use of a starting angle of 165° for the first head placed the overlapping portion of the orbits over the LAO myocardial region, where camera-cardiac distance is most favorable. Use of this overlapping orbit yielded resolution equivalent to a conventional (single-head) 180° rotation. Sensitivity was 87%–90% of that of a 90° dual-detector system, and 16%–20% better than the common practice of using a 120° orbit with reconstruction of 1 /12 heads to achieve 180° of data. Use of 360° acquisition with reconstruction of all three heads provided the greatest sensitivity, though at the expense of some loss in image quality. Thus, for those centers performing cardiac imaging using a triple-detector system, use of overlapping 180° orbits is the preferred acquisition choice.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Coleman RE, Jaszczak RJ, Cobb FR. Comparison of 180° and 360° data collection in thallium-201 imaging using single-photon emission computerized tomography (SPECT): concise communication.J Nucl Med 1982; 23: 655–660.

    Google Scholar 

  2. Tamaki N, Mukai T, Ishil Y, Fujita T, Yamamoto K, Minato K, Yonekura Y, Tamaki S, Kambara H, Kawai C, Torizuka K. Comparative study of thallium emission myocardial tomography with 180° and 360° data collection.J Nucl Med 1982; 23: 661–666.

    Google Scholar 

  3. Go RT, MacIntyre WJ, Houser TS, Pantoja M, O'Donnell JK, Feiglin DH, Sufka BJ, Underwood DA, Meaney TF. Clinical evaluation of 360° and 180° data sampling techniques for transaxial SPECT thallium-201 myocardial perfusion imaging.J Nucl Med 1985; 26: 695–706 (also see comments in vol 27: 146–149).

    Google Scholar 

  4. Eisner RL, Nowak DJ, Pettigrew R, Fajman W. Fundamentals of 180° acquisition and reconstruction in SPECT imaging.J Nucl Med 1986; 27: 1717–1728.

    Google Scholar 

  5. Keyes JW. SPECT and artifacts — in search of the imaginary lesion.J Nucl Med 1991; 32: 875–877.

    Google Scholar 

  6. Miller TR, Wallis JW, Wilson AD. Interactive reconstruction in single-photon tomography.Eur J Nucl Med 1989; 15: 189–193.

    Google Scholar 

  7. Miller TR, Starren J, Grothe R. Three-dimensional display of positron emission tomography of the heart.J Nucl Med 1988; 29:530–537.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wallis, J.W. Increased sensitivity through use of overlapping 180° orbits in clinical myocardial perfusion imaging. Eur J Nucl Med 22, 543–547 (1995). https://doi.org/10.1007/BF00817279

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00817279

Key words

Navigation