Conclusions
Limitation of the unbalance moment of the first link is an indispensable condition for stabilizing the counting mechanism's opposing moment.
An optimum setting of the distance between centers in the first worm transmission leads to a reduction of the opposing moment down to 12%.
In order to raise the opposing moment's stabilization, it is advisable to limit the displacement of the gear mean plane with respect to the worm in the register worm transmission.
Similar content being viewed by others
Literature cited
G. A. Talalaev, Mokslas ir Technika (Nauka i Tekhnika) [in Lithuanian], No. 1, AN LitSSR (1971).
G. A. Talalaev and I. P. Abloževičjus, Materials of the 21st Republican Scientific and Technical Conference, Kaunas (1971).
G. A. Talalaev, Pribory i Sistemy Upravleniya, No. 12 (1971).
G. A. Talalaev, Izmeritel'. Tekh., No. 4 (1971).
RTM 44-62, “Method for statistical processing of empirical data,” Standartgiz, Moscow (1963).
Additional information
Translated from Izmeritel'naya Tekhnika, No. 2, pp. 56–58, February, 1973.
Rights and permissions
About this article
Cite this article
Talalaev, G.A. Effect of manufacturing errors on the instantaneous characteristics of counting mechanisms. Meas Tech 16, 247–249 (1973). https://doi.org/10.1007/BF00812566
Issue Date:
DOI: https://doi.org/10.1007/BF00812566