Evaluation of signal distortions in magnetic recording with pulse modulation

  • General Problems of Metrology and Measurement Techniques
  • Published:
Measurement Techniques Aims and scope

Conclusions

  1. 1.

    The expressions thus obtained serve to evaluate signal distortions due to tape velocity fluctuations and to SAM in PFM and PPM recording.

  2. 2.

    In order to account for the effect of SAM on PFM recording, it is necessary to know the Ordinate of the correlation function KA (τ) of the response amplitude variations process A (t) for the argument τ=T0.

  3. 3.

    In evaluating the PPM recording distortions it is necessary to take into account the correlation of response amplitude envelopes in a single track and mutual correlations of the envelopes in tracks used for reference and information signals.

  4. 4.

    The effect of the SAM component depends on the resolution of the magnetic tape-head system and the modulation parameters. This component can be made adequately small by a correct selection of the above factors.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature cited

  1. B. M. Stepanov and V. N. Filinov, Izmeritel'. Tekh., No. 7 (1966).

  2. B. M. Stepanov and V. N. Filinov, Izmeritel'. Tekh., No. 9 (1966).

Download references

Authors

Additional information

Translated from Izmeritel'naya Tekhnika, No. 2, pp. 15–18, February, 1973.