Summary
In this paper we report the complete separation of amino acids as DABS-derivatives using a 3µm Supelcosil LC-18 (25 cm × 2.1 mm I.D.) narrowbore column. The system described makes it possible to perform the analysis of DABS-amino acids with a sensitivity to the femtomole level. We have also studied the conditions necessary for using the narrow-bore columns for routine analysis, paying particular attention to the problem of providing adequate protection for the analytical column. We have found it very suitable to use a (2 cm × 2.1 mm I.D.) guard column filled with a 40µm Pelliguard LC-18, pellicular packing resin, without affecting the complete resolution of the DABS-amino acids. Comparing the results obtained using conventional HPLC columns (3–5µm Supelcosil LC-18) of different lengths (15 and 25 cm × 4.6 mm I.D.) with those obtainable with the narrow-bore columns used in this work, it is possible to achieve a much greater sensitivity using the narrow-bore columns. In short, using the appropriate guard column and the “standard” HPLC apparatus used, the narrow-bore columns are very useful for routine analyses of DABS-amino acids with a sensitivity at the femtomole level.
Similar content being viewed by others
References
Benson JR, Hare PE (1975) Proc Natl Acad Sci USA 72: 619–622
Bohlen P, Schroeder R (1982) Anal Biochem 126: 144–156
Bayer E, Grom E, Kaltenegger B, Uhman R (1976) Anal Chem 48: 1106–1109
Cronin JR, Hare PE (1977) Anal Biochem 81: 151–156
Cooper HDJ, Ogden G, McIntosh J, Turnell CD (1984) Anal Biochem 142: 98–102
Chang J-Y, Knecht R, Braun G (1981) Biochem J 199: 547–556
Chang J-Y, Martini P, Bernasconi R, Braun GD (1981) FEBS Lett 132: 117–120
Chang J-Y, Knecht R, Braun DG (1982) Biochem J 203: 803–806
Chang J-Y, Knecht R, Braun DG (1983) Methods in enzymology, vol 91. Academic Press, New York, p 41
Chang J-Y (1984) J Chromatogr 295: 193–120
De Jong C, Hughes JG, Van Vieringen E, Wilson KJ (1982) J Chromatogr 241: 345–359
Engelhart H, Asshauer J, Neve U, Weigand N (1974) Anal Chem 46: 336–340
Hughes JG, Frutiger S, Fonk C (1987) J Chromatogr 389: 327–333
Knecht R, Chang J-Y (1986) Anal Chem 58: 2375–2379
Kaneda N, Stato M, Yagi K (1982) Anal Biochem 127: 49–54
Negro A, Garbisa S, Gotte L, Spina M (1987) Anal Biochem 160: 39–46
Spackman HD, Moore S, Stein HW (1958) Anal Chem 30: 1190–1198
Stocchi V, Cucchiarini L, Piccoli G, Magnani M (1985) J Chromatogr 349: 77–82
Stocchi V, Piccoli G, Magnani M, Palma F, Biagiarelli B, Cucchiarini L (1989) Anal Biochem 178: 107–117
Schmidt GJ, Olson DG, Slavin W (1979) J Liq Chromatogr 2: 1031–1045
Tapuhi Y, Schmidt DE, Linder W, Karger BL (1981) Anal Biochem 115: 123–129
Vendrell J, Aviles XF (1986) J Chromatogr 358: 401–413
Winkler G, Heinz XF, Kunz C (1984) J Chromatogr 297: 63–73
Wilkinson JM (1979) J Chromatogr Sci 16: 547–552
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Stocchi, V., Palma, F., Piccoli, G. et al. Analysis of amino acids as DABS-derivatives with a sensitivity to the femtomole level using RP-HPLC narrow-bore columns. Amino Acids 3, 303–309 (1992). https://doi.org/10.1007/BF00806005
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00806005