Prevalence of microembolic signals in patients with different types of mono-leaflet and bi-leaflet prosthetic heart valves

  • Original
  • Published:
The Italian Journal of Neurological Sciences Aims and scope Submit manuscript

Abstract

Microembolic signals (MES) have been described in patients with different types of prosthetic valves. The aim of our study was to compare prevalence of MES in patients with mono-leaflet and bi-leaflet valves, and to correlate them with different clinical and echocardiographic parameters. We evaluated 42 patients, 15 with mono-leaflet and 27 with bi-leaflet valves, with 30-minute bilateral simultaneous transcranial Doppler monitoring for the identification of MES. All patients performed blood testing for international normalized ratio (INR), color-coded duplex of supra-aortic vessels, and echocardiography. Eighteen patients (43%) showed MES; 61% of MES were detected bilaterally, 17% only on the left and 22% only on the right middle cerebral artery (MCA), with no interhemispheric difference. MES did not correlate with patient's age, echocardiographic parameters, INR, presence of atrial fibrillation, or site of valve replacement. One (7%) of the 15 patients with mono-leaflet valves had MES, as opposed to 17 (63%) of the 27 with bi-leaflet valves (p=0.0003). Patients with bileaflet valves and MES had valves of older implantation and, only for aortic valves, larger valve size.

Sommario

I soggetti con valvole cardiache artificiali manifestano frequenti segnali microembolici (MES) al Doppler transcranico: scopo dello studio è di valutare tali fenomeni in soggetti con valvole mono-disco e bi-disco. Abbiamo esaminato con monitoraggio bilaterale transcranico 42 pazienti, di cui 15 portatori di valvole mono-disco e 27 di valvole bi-disco. Per ogni soggetto sono stati registrati i parametri coagulativi ed ecocardiografici, ed e stato effettuato esame eco-Doppler dei vasi sopraaortici. Diciotto pazienti su 42 (43%) hanno manifestato MES, di cui 61 % bilaterali, 17% a sinistra e 22% a destra. Non è stata evidenziata alcuna correlazione significativa tra presenza di MES ed èta del paziente, presenza di fibrillazione atriale, valori di (international normalized ratio), dimensioni delle camere cardiache al-l'ecocardiogramma, sede delta valvola. Un solo paziente su 15 (7%) con valvole mono-disco presentava MES, mentre 17 su 27 (63%) con valvole bi-disco presentava tale fenomeno (p=0.0003). I pazienti con valvole bi-disco e MES avevano valvole di impianto più remoto e, solo per le valvole a sede aortica, dimensioni valvolari maggiori.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Breakken SK, Russel D, Brucher R, Svennevig J (1995) Incidence and frequency of cerebral embolic signals in patients with a similar bileaflet mechanical heart valve. Stroke 26:1225–1230

    Google Scholar 

  2. Georgiadis D, Grosset DG, Kelman AW, Faichney A, Lees KR (1994) Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves. Stroke 25:587–592

    Google Scholar 

  3. Georgiadis D, Kaps M, Siebler M, Hill M, Konig M, Erg J, Kahl M, Zunker P, Diehl B, Ringelstein EB (1995) Variability of Doppler microembolic signal counts in patients with prosthetic cardiac valves. Stroke 26:439–443

    Google Scholar 

  4. Grosset DG, Georgiadis D, Kelman AW, Lees KR (1993) Quantification of ultrasound emboli signals in patients with cardiac and carotid disease. Stroke 24:1922–1924

    Google Scholar 

  5. Sliwka U, Diehl R.R, Meyer B, Schondube F, Noth J (1995) Transcranial Doppler high intensity signals in the acute phase and long term follow up of mechanical heart valve implantation. J Stroke Cerebrovascular Dis 5:139–146

    Google Scholar 

  6. Georgiadis D, Mallison A, Grosset DG, Less KR (1994) Coagulation activity and emboli counts in patients with prosthetic cardiac valves. Stroke 25:1211–1214

    Google Scholar 

  7. Consensus Committee of the 9th International Cerebral Hemodynamic Symposium (1995) Basic identification criteria of Doppler microembolic signals. Stroke 26:1123

    Google Scholar 

  8. Ringelstein EB, Droste DW, Babikian VL, Evans DH, Grosset DG, Kaps M, Markus HS, Russel D, Siebler M (1998) Consensus on microembolus detection by TCD. International Consensus Group on Microembolus Detection. Stroke 29:725–729

    Google Scholar 

  9. Infeld B, Bowser DN, Gerraty RP, Voukelatos J, Grigg L, Mitchell PJ, Hopper JL, Davis SM (1996) Cerebral microemboli in atrial fibrillation detected by transcranial Doppler ultrasonography. Cerebrovasc Dis 6:339–345

    Google Scholar 

  10. Berg J, Kaps M, Jauss M (1996) Do hits have predective value for stroke risk in patients with prosthetic cardiac valves? Cerebrovascular Dis 6[Suppl 3]:67 (abstr)

    Google Scholar 

  11. Kaps M, Sedel G, Berg J (1995) Is there a hemispheric side preference of cardiac valvular emboli? Ultrasound Med Biol 21:735–736

    Google Scholar 

  12. Droste DW, Hansberg T, Kemeny V, Hammel D, Shulte-Altedorneburg G, Nabavi DG, Kaps M, Scheld HH, Ringelstein EB (1997) Oxygen inhalation can differentiate gaseous from non-gaseous microemboli detected by transcranial Doppler ultrasound. Stroke 28:2453–2456

    Google Scholar 

  13. Kaps M, Hansen J, Weiher M, Tiffert K, Kayser I, Droste DW (1997) Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid. Stroke 28:322–325

    Google Scholar 

  14. Del Sette M, Angeli S, Gandolfo C (1998) Warfarin, aspirin and microembolic signals in the acute phase of stroke in a patient with mechanical heart valves. Cerebrovasc Dis 8:182–183

    Google Scholar 

  15. Sliwka U, Georgiadis D (1998) Clinical correlations of Doppler microembolic signals in patients with prosthetic cardiac valves. Stroke 29:140–143

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Del Sette, M., Angeli, S., Badano, L. et al. Prevalence of microembolic signals in patients with different types of mono-leaflet and bi-leaflet prosthetic heart valves. Ital J Neuro Sci 19, 311–314 (1998). https://doi.org/10.1007/BF00713858

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00713858

Key words

Navigation