Abstract
Small cylinders of a new composite porous material consisting of a dense alumina core coated with two layers of beads of the same material, bonded to each other and to the underlying surface by a high-temperature melting glass have been implanted in the proximal femurs of rabbits. The explants were carried out 1, 4, 6, 8, and 18 weeks after surgery. The bone fragment containing the implant was embedded in methyl methacrylate without performing decalcification, and morphological observations were carried out. These showed that four weeks after surgery it is already possible to observe the development of bone spicules in the implant porosities. Along with these studies, microhardness measurements were carried out by using a microhardness tester connected to an image analyser. The mineralized tissue in close contact with the implant showed, one month after surgery, a compression strength similar to that of healthy bone.
Similar content being viewed by others
References
R. M. PILLAR,J. Biomed. Mater. Res. A121 (1987) 1.
J. L. WOODMAN, J. J. JACOBS, J. O. GALANTE and R. M. URBAN, in Transactions of the 28th Annual Meeting Orthopaedic Research Society, Vol. 7, New Orleans, LA, January 19–21 (1982).
P. DUCHEYNE, G. WILLEMS, M. MARTENS and J. HELSEN,J. Biomed. Mater. Res. 18 (1984) 293.
A. K. HEDLEY and S. C. KOZIM, in “Total knee arthroplasty”, edited by D. S. Hungerford, K. A. Krackow and R. W. Kenna (Williams and Wilkins, London, 1984) p. 89.
A. PIZZOFERRATO, A. TONI, A. VENTURINI, A. SUDANESE, N. BALDINI, G. CIAPETTI and S. STEA, in “Biomaterials and clinical applications”, edited by A. Pizzoferrato, P. G. Marchetti, A. Ravaglioli and A. J. C. Lee (Elsevier, 1987) p. 52.
A. PIZZOFERRATO, A. TONI, A. SUDANESE, G. CIAPETTI, A. TINTI and A. VENTURINI,J. Biomed. Mater. Res. 22 (1988) 1181.
A. UCHIDA, S. NADE, E. McCARTNEY and W. CHING,J. Orthop. Res. 31 (1985) 65.
D. F. WILLIAMS, in “Biocompatibility of orthopaedic implants”, Vol. II, edited by D. F. Williams (CRC Press, Boca Raton, FL, 1982) p. 49.
M. SPECTOR, in “Biocompatibility of orthopaedic implants”, Vol. II, edited by D. F. Williams (CRC Press, Boca Raton, FL, 1982) p. 55.
——Idem., in “Biocompatibility of orthopaedic implants”, Vol. II, edited by D. F. Williams (CRC Press, Boca Raton, FL, 1982) p. 89.
J. BLACK, in “Orthopaedic biomaterials in research and practice” (Churchill Livingstone, New York, 1988) p. 267.
P. DUCHEYNE, in “Handbook of biomaterials evaluation”, edited by A. Von Recum (Macmillan, New York, 1986) p. 73.
D. CARLSTROM,Experientia 10 (1954) 171.
J. K. WEAVER,J. Bone Joint Surg. A48 (1966) 273.
S. LEES,J. Biomech. 14 (1966) 561.
G. MAROTTI, A. FAVIA and A. ZAMBONIN ZALONE,Calcif. Tissue Res. 10 (1972) 67.
A. PIZZOFERRATO, P. LEGGERI, C. TARABUSI and D. L. LEAKE, “Ceramics in surgery”, edited by P. Vincenzini (Elsevier, Amsterdam, 1983) p. 149.
H. YAMADA, (R. E. Krieger, Huntington, NY, 1973) p. 45.
J. C. KELLER, F. A. YOUNG and J. R. NATIELLA,J. Biomed. Mater. Res. 21 (1987) 305.
J. D. BOBYN, R. M. PILLAR, H. V. KAMERON and G. C. WEATHERLY,Clin. Orthop. Rel. Res. 150 (1980) 263.
P. DUCHEYNE, in “Functional behaviour of orthopedic biomaterials”, Vol. II, edited by P. Ducheyne and G. W. Hastings (CRC Press, Boca Raton, FL, 1984) p. 163.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Stea, S., Tarabusi, C., Ciapetti, G. et al. Microhardness evaluations of the bone growing into porous implants. J Mater Sci: Mater Med 3, 252–254 (1992). https://doi.org/10.1007/BF00705289
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00705289