Abstract
Wave propagation in a step-index optical fibre with a curved section is treated theoretically. Mode conversion and radiation take place. The mode coupling coefficients which depend on the polarization of the incident mode are calculated. Radiation losses at the transition between a straight and a curved fibre section and total losses including the continuous radiation loss due to a uniform bend are evaluated. Comparisons are also made between singly and doubly clad fibres. It is shown that the doubly clad fibre can tolerate a sharper bend.
Similar content being viewed by others
References
E. G. Neuman andH. D. Rudolph,IEEE Trans. MTT-23 (1975) 142–9.
J. A. Arnaud,Bell Syst. Tech. J. 53 (1974) 1379–94.
L. Lewin,IEEE Trans. MTT-22 (1974) 718–27.
idem, ibid MTT-23 (1975) 779.
E. F. Kuester andD. C. Chang,IEEE J. Quant. Electron. QE-11 (1975) 903–7.
M. Kuhn,Arch. Elekt. Übertrag. 28 (1974) 393–401.
P. L. Chu,Electron. Lett. 10 (1974) 459–60.
S. Kawakami andS. Nishida,IEEE J. Quant. Electron. QE-11 (1975) 130–8.
M. Miyagi andG. L. Yip,Opt. Quant. Elect. 8 (1976) 335–41.
S. Kawakami, M. Miyagi andS. Nishida,Appl. Opt. 14 (1975) 2588–97.
Author information
Authors and Affiliations
Additional information
Requests for reprints should be sent to Professor G. L. Yip.
Rights and permissions
About this article
Cite this article
Miyagi, M., Yip, G.L. Mode conversion and radiation losses in a step-index optical fibre due to bending. Opt Quant Electron 9, 51–60 (1977). https://doi.org/10.1007/BF00624272
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00624272