Abstract
A Fabry-Perot interferometer is used in the wedge mode to examine the line width with a passive Q switch. The width is found to fall from 0.2 cm−1 in free oscillation to 0.005 cm−1 in the single-pulse mode.
Similar content being viewed by others
References
T. V. Gvaladze, I. K. Krasyuk, P. P. Pashinin, A. V. Prokhindeev, and A. M. Prokhorov, ZhETF,48, 106, 1965.
B. H. Soffer, J. Appl. Phys.,35, 2551, 1964.
F. A. Korolev, Vestnik Mosk. Univ., ser. mekh., mat., astron., fiz., khim., no. 7, 101, 1953.
F. J. McClung, and D. Weiner, IEEE J. Quant. Electron.,1, no. 2, 94, 1965.
A. M. Leontovich and A. P. Veduta, ZhETF,46, 71, 1964.
G. Bret, and F. Gires, Appl. Phys. Letters,4, no. 10, 175, 1964.
Additional information
We are indebted to O. L. Lebedev and V. K. Kolesnikova for assistance in this work.
Rights and permissions
About this article
Cite this article
Borovitskii, S.I., Gryaznov, Y.M. & Chastov, A.A. Line width of a ruby laser with a liquid switch. J Appl Spectrosc 5, 445–447 (1966). https://doi.org/10.1007/BF00608870