Skip to main content
Log in

Hydrophilic polymer-coated guide wire combined with progressive suppleness pursil catheter for safer, more definitive embolisation of arteriovenous malformations

  • Interventional Neuroradiology
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

For safe, more definitive embolisation of arteriovenous malformations, improved selectivity of the catheter is desirable. This report describes the advantage of the combined use of a progressive suppleness pursil catheter and a hydrophilic polymer-coated guide wire, together with precaution against complications. In 14 patients, 27 vessels were catheterised with this. Chemical embolisation using oestrogen alcohol and polyvinyl acetate was carried out only if sufficiencytly superselective catheterization was achieved with negative results on a provocation test. Chemical embolisation was successful in 25 vessels, but in three vessels catheterised very distally, it required much more time to withdraw the catheter because of the friction between it and the wall of the vessel.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Dion JE, Duckwiler GR, Lylyk P, Viñuela F, Bentson J (1989) Progressive suppleness pursil catheter: a new tool for superselective angiography and embolization. AJNR 10:1068–1070

    Google Scholar 

  2. Takayasu K, Muramatsu Y, Moriyama N, Ohtsu T, Catapia FC (1988) Plastic-coated guide wire for hepatic arteriography. Radiology 166:545–546

    Google Scholar 

  3. Dawson RC, Tarr RW, Hecht ST, Jungreis CA, Lunsford LD, Coffey R, Horton JA (1990) Treatment of arteriovenous malformations of the brain with combined embolization and stereotactic radiosurgery: results after 1 and 2 years. AJNR 11:857–864

    Google Scholar 

  4. Rodesch G, Lasjaunias P (1991) Treatment of arteriovenous malformations (letter). AJNR 12:1023–1024

    Google Scholar 

  5. Su C-C, Takahashi A, Yoshimoto T, Sugawara T (1991) Histopathological studies of a new liquid embolization method using estrogen-alcohol and polyvinyl acetate. Surg Neurol 36:4–11

    Google Scholar 

  6. Takahashi A, Yoshimoto T, Sugawara T (1991) New liquid embolization method for brain arteriovenous malformations: Combined infusion of oestrogen-alcohol and polyvinyl acetate. Neuroradio 33 (Suppl):190–192

    Google Scholar 

  7. Sugawara T, Takahashi A, Su CC, Suga T, Yoshimoto T, Suzuki J (1992) Expermintal investigation of a new liquid embolization method Enhancing effect of 25% ethanol on conjugated estrogen. Neurol Med Chir 32:59–64

    Google Scholar 

  8. Mizoi K, Takahashi A, Yoshimoto T, Sugawara T, Saito K (1992) Surgical excision of giant cerebellar hemispheric arteriovenous malformations following preoperative embolization. J Neurosurg 76:1008–1011

    Google Scholar 

  9. Kikuchi Y, Strother CM, Boyer M (1987) New catheter for endovascular interventional procedures. Radiology 165:870–871

    Google Scholar 

  10. Pinto RS, Robbins E, Seidenwurm D (1989) Thrombogenicity of teflon versus copolymer-coated guidewires: evaluation with scanning electron microscopy. AJNR 10:407–410

    Google Scholar 

  11. Goto K, Taki W, Iwata H (1991) A new technique for embolization of cerebral arteriovenous malformations and dural arteriovenous fistulae. Neuroradiology 33 (Suppl):193–194

    Google Scholar 

  12. Goto K (1991) Low-friction high-torque guide wire: A new way for superselective catheterization. Neuroradiology 33 (Suppl): 636–637

    Google Scholar 

  13. Goto K (1988) Cerebral and cranial artery navigation without using a leak balloon: a new combination of a low-friction high torque guide wire and a thin supple catheter. AJNR 9:1040

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ezura, M., Takahashi, A., Yoshimoto, T. et al. Hydrophilic polymer-coated guide wire combined with progressive suppleness pursil catheter for safer, more definitive embolisation of arteriovenous malformations. Neuroradiology 36, 326–329 (1994). https://doi.org/10.1007/BF00593273

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00593273

Key words

Navigation