Abstract
To quantify the interdependence of capillary leukocyte plugging and microvascular hemodynamics, experimental measurements were made of the time required for lymphocytes and granulocytes to enter a micropipette. Using standard micropipette deformation techniques, entrance times were found to be a function of both cell diameter and pipette diameter, with no significant dependence on aspiration pressure over the differential pressure range of 200–400 Pa. Experimental results were combined with a computer network model to describe changes in red cell distribution and flow rate resulting from the delayed entrance of leukocytes (WBC) into capillaries. The network model is based on geometrical measurements from the capillary bed of a hamster cremaster muscle (Sarelius et al. 1981) and utilizes previous work describing: 1. preferential cell distribution at a bifurcation, 2. increased apparent viscosity due to the presence of red and white cells, and 3. increased velocities of red and white cells relative to blood. Red and white cell positions within the network were computed at discrete time increments, and WBC plugging was simulated by a temporary cessation of flow in vessels of smaller diameter than the white cell. In contrast with previous studies, the increased viscosity due to the presence of WBCs was found to have an insignificant effect on overall network flow rate. Instead, a major flow reduction occurs only when capillaries are plugged by the white cells. At normal physiological concentrations (1,000 RBC/WBC), time-averaged overall network flow is reduced by 4.4%, based on averaged experimentally measured entrance times, and up to 14.8% if maximal entrance times are used. Overall flow rates fluctuate significantly with time and, at concentrations greater than 1 WBC/200 RBC, decrease substantially with increasing WBC concentration. At levels comparable to acute leukemia (70 RBC/WBC), flow is severely compromised due to numerous WBC occlusions. In the absence of WBCs, mean hematocrit and hematocrit distribution compare well with published values. Spatial variations in hematocrit are notable, however, and capillaries originating from the upstream end of the arteriole have a much lower hematocrit than downstream branches (by a factor of two, on average) due to preferential distribution of red blood cells.
Similar content being viewed by others
References
Bagge U, Branemark P-I (1977) White blood cell rheology. An intravital study in man. Adv Microcir 7:1–17
Bagge U, Amundson B, Lauritzen C (1980) White blood cell deformability and plugging of skeletal muscle capillaries in hemorrhagic shock. Acta Physiol Scand 180:159–163
Boyum A (1968) Isolation of mononuclear cells and granulocytes from human blood. Scan J Clin Lab Invest 21 (suppl 97):77–89
Braide M, Amundson B, Chien S, Bagge U (1984) Quantitative studies on the influence of leukocytes on the vascular resistance in a skeletal muscle preparation. Microvas Res 27:331–352
Chen TC, Skalak R (1970) Stokes flow in a cylindrical tube containing a line of spheroidal particles. Appl Sci Res 22:403–441
Engler RL, Schmid-Schoenbein GW, Pavelec RS (1983) Leukocyte capillary plugging in myocardial ischemia and reperfusions in the dog. Am J Pathol 111:98–111
Evans E (1984) Structural model for passive granulocyte behaviour based on mechanical deformation and recovery after deformation tests. In: White cell mechanics: Basic science and clinical aspects. Alan R Liss, Inc, New York, pp 53–71
Fenton BM, Carr RT, Cokelet GR (in press) Nonuniform red cell distribution in 20–100 micron bifurcations. Microvas Res
Gaehtgens P, Albrecht KH, Kreutz F (1978) Fahraeus effect and cell screening during tube flow of human blood. I. Effect of variation of flow rate. Biorheol 15:147–154
Hochmuth RM, Sutera SP (1970) Spherical caps in low Reynolds-number tube flow. Chem Eng Sci 25:593–604
Johnson PC, Blaschke J, Burton KS, Diol JG (1971) Influence of flow-variations on capillary hematocrit in mesentery. Am J Physiol 221:105–112
Kanzow G, Pries AR, Gaehtgens P (1981) Flow dependent hematocrit distribution in microvessel networks. Bibl Anat 20:149–152
Lichtman MA (1984) The relationship of excessive white cell accumulation to vascular insufficiency in patients with leukemia. In: White cell mechanics: Basic science and clinical aspects. Alan R Liss, Inc, New York, pp 295–306
Lichtman MA, Kearney EA (1976) The filterability of normal and leukemic human leukocytes. Blood Cells 2:491–506
Lichtman MA, Rowe JM (1982) Hyperleukocytic leukemias: rheological, clinical, and therapeutic considerations. Blood 60:279–293
Lichtman MA, Weed RI (1972) Alteration of the cell periphery during granulocyte maturation: Relationship to cell function. Blood 39:301–316
Lipowsky HH, Zweifach BW (1974) Network analysis of microcirculation of cat mesentery. Microvasc Res 7:73–83
Miller ME, Myers KA (1975) Cellular deformability of the human peripheral blood polymorphonuclear leukocyte: method of study, normal variation and effects of physical and chemical alterations. J Reticuloendo Soc 18:337–345
Nicoll PA, Webb RL (1946) Blood circulation in the subcutaneous tissue of the living bat's wing. Ann NY Acad Sci 46:697–711
Palmer AA (1967) Platelet and leukocyte skimming. Bibl Anat 9:300–303
Sarelius IH, Damon DN, Duling BR (1981) Microvascular adaptations during maturation of striated muscle. Am J Physiol 241:H317-H324
Sarelius IH, Duling BR (1982) Direct measurement of microvessel hematocrit, red cell flux, velocity, and transit time. Am J Physiol 243:H1018-H1026
Schmid-Schoenbein GW, Skalak R, Usami S, Chien S (1980) Cell distribution in capillary networks. Microvasc Res 19:18–44
Segal GB, Cokelet GR, Lichtman MA (1981) The measurement of lymphocyte volume: Importance of reference particle deformability and counting solution tonicity. Blood 57:894–899
Skalak R, Chen PH, Chien S (1972) Effect of hematocrit and rouleaux on apparent viscosity in capillaries. Biorheol 9:67–82
Sutera SP, Seshadri V, Croce PA, Hochmuth RM (1970) Capillary blood flow. II. Deformable model cells in tube flow. Microvasc Res 2:420–433
Tvetenstrand CD, Farrell Epstein MA, Schmidt-Schoenbein GW, Chien S. Model studies on distributions of white and red blood cells at microvascular bifurcations. Am J Physiol (in review)
Wang H, Skalak R (1969) Viscous flow in a cylindrical tube containing a line of spherical particles. J Fluid Mech 38:75–96
Wilson JW (1972) Leukocyte sequestration and morphologic augmentation in the pulmonary network following hemorrhagic shock and related forms of stress. Adv Microcirc 4:197–232
Yen RT, Fung YC (1978) Effect of velocity distribution on red cell distribution in capillary blood vessels. J Physiol 235(2):H251-H257
Author information
Authors and Affiliations
Additional information
Support for this research was obtained under NIH Grants HL-23355 and HL-18208; this paper is partially based on work performed under contract No. DE-AC02-76EV03490 with the U.S. Department of Energy at the University of Rochester Department of Radiation Biology and Biophysics and has been assigned report No. DOE/EV/03490-2415
Rights and permissions
About this article
Cite this article
Fenton, B.M., Wilson, D.W. & Cokelet, G.R. Analysis of the effects of measured white blood cell entrance times on hemodynamics in a computer model of a microvascular bed. Pflugers Arch. 403, 396–401 (1985). https://doi.org/10.1007/BF00589252
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00589252