The measurement of low flow rates (0.1–30 ml/min) of conducting fluids

  • Transport Processes, Metabolism and Endocrinology; Kidney, Gastrointestinal Tract, and Exocrine Glands
  • Instruments and Techniques
  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Abstract

The accurate measurement of flow rates in isolated-organ perfusion experiments remains a problem. This paper describes an instrument that is based upon the familiar drop counter, but permits greater accuracy, resolution and convenience of recording output than has hitherto been available with such a device. Long-term stability at low flow rates is excellent. The input transducer is a conventional drip chamber with platinum electrodes arranged so that each drop produces an electrical pulse. The time between pulses is measured (or groups of 10 pulses for higher flow rates) and a voltage ouput proportional to flow is derived by analogue computing elements. Calibration requires only the measurement of the volume of drops forming at very low flows, and a simple procedure to do this is described. Four switched ranges covering 0.1–30 ml/min are provided, and the agreement between flow recorded by the instrument and by timed collections of perfusate is generally better than 30% of full scale.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Condon NE (1913) A magnet-tipper for recording outflow. J Physiol XLVI:xlvi

    Google Scholar 

  • Gaddum JH (1929) An outflow recorder. J Physiol 67:xvi-xvii

    Google Scholar 

  • Jacobsen IA, Pegg DE, Wusteman MC, Robinson SM (1978) Transplantation of rabbit kidneys perfused with glycerol solutions at 10°C. Cryobiology 15:18–26

    Google Scholar 

  • Lutz J (1972) Druckkonstante Perfusion von Teilkreisläufen mittels einer druckgesteuerten Rollenpumpe mit analoger Durchströmungsregistrierung. Pflügers Arch 335 (Suppl):R 89

    Google Scholar 

  • Lutz J, Henrich H (1970) Gefäßkontraktionen in situ bei druck- und stromkonstanter Perfusion der intestinalen Strombahn und ihre Abhängigkeit vom Ausgangsdruck. Pflügers Arch 319:68–81

    Google Scholar 

  • Pegg DE (1966) Electro-mechanical flow transducer for physiological fluids. Phys Med Biol 11:113–117

    Google Scholar 

  • Pegg DE (1974) Perfusion technology. In: Organ preservation for transplantation, 2nd edn. Marcel Dekker, New York, pp 447–495

    Google Scholar 

  • Pegg DE, Green CJ (1973) Renal preservation by hypothermic perfusion. 1. The importance of pressure-control. Cryobiology 10:56–66

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pegg, D.E., Hayes, A.R. & Diaper, M.P. The measurement of low flow rates (0.1–30 ml/min) of conducting fluids. Pflugers Arch. 401, 209–212 (1984). https://doi.org/10.1007/BF00583884

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00583884

Key words

Navigation