Skip to main content
Log in

Geräte zur Messung der magnetooptischen Aktivität

I. Die magnetooptische Rotation

  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

For measuring the magnetic optical rotation a recording spectropolarimeter is used, the sample compartment of which is large enough to store the necessary magnet unit. When examining dilute solutions a double magnet having contrary magnetic field directions has proven to be effective to compensate for the magnetic rotation of the solvent. Besides a simple correction for the different densities of the solvent and the solution a systematic error has to be taken into consideration, which results from a reflection in the sample cell and may erroneously be taken for Cotton effects.

Zusammenfassung

Zur Messung der magnetooptischen Rotationsdispersion wird ein registrierendes Spektralpolarimeter verwendet, dessen Probenraum so groß ausgelegt ist, daß sich darin die zusätzlich notwendige Magneteinheit unterbringen läßt. Bei Untersuchungen an verdünnten Lösungen hat sich zur Kompensation der Magnetorotation des Lösungsmittels ein Doppelmagnet mit entgegengesetzten Magnetfeldeinrichtungen bewährt. Neben einer leicht durchführbaren Korrektur für unterschiedliche Dichten von Lösungsmittel und Lösung muß bei der Auswertung der gemessenen Spektren ein systematischer Fehler berücksichtigt werden, der durch Reflexionen innerhalb der Küvetten entsteht, und der Cotton-Effekte vortäuschen kann.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Briat, B.: Compt. Rend.258, 2788 (1964).

    Google Scholar 

  2. —,M. Billardson etJ. Badoz: Compt. Rend.256, 3440 (1963).

    Google Scholar 

  3. —, etM. Le Liboux: Compt. Rend.262, 803 (1966).

    Google Scholar 

  4. Buckingham, A. D., andP. J. Stephens: Ann. Rev. Phys. Chem.17, 399 (1966).

    Google Scholar 

  5. Löffler, H., u.M. Mächler: Zeiss Information14, 40 (1966).

    Google Scholar 

  6. McCaffery, A. J., G. N. Henning, P. N. Schatz, A. B. Ritchie, H. P. Perzanowski, O. R. Rodig, A. W. Norvelle jr., andP. J. Stephens: Chem. Commun.15, 520 (1966).

    Google Scholar 

  7. Partington, J. R.: An advanced treatiase on physical chemistry, Vol. IV. London 1953.

  8. Schatz, P. N., A. J. McCafferey, W. Suëtaka, G. N. Henning, A. B. RitChie, andP. J. Stephens: J. Chem. Phys.45, 722 (1966).

    Google Scholar 

  9. Schooley, D. A., E. Bunnenberg, andC. Djerassi: Proc. Nat. Acad. Sci.56, 1377 (1966).

    Google Scholar 

  10. Shashoua, V. E.: J. Am. Chem. Soc.86, 2109 (1964).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Wir danken der Stiftung Volkswagenwerk für die großzügige finanzielle Unterstützung dieser Arbeit.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Winkler, J. Geräte zur Messung der magnetooptischen Aktivität. Z. Anal. Chem. 235, 18–29 (1968). https://doi.org/10.1007/BF00568843

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00568843

Navigation