Skip to main content
Log in

The use of immunoelectrophoretic apparatus for rapid diagnosis

  • Exchange Of Experience
  • Published:
Biomedical Engineering Aims and scope

Conclusions

1. The PÉFAG-1 apparatus and its portable small-scale version can be used not only to detect hepatitis B antigen, but also to detect antigens of tick-borne encephalitis and meningococcal infection and other bacterial and viral antigens for the diagnosis of infectious diseases.

2. The sensitivity of determination of antigens and antibodies on the PÉFAG-1 apparatus was found to be 2–3 times higher than radial immunodiffusion and 10–20 times higher than countercurrent immunodiffusion.

3. When the PÉFAG-1 apparatus is used to diagnose virus hepatitis results can be obtained in 30–45 min, compared with 10–15 min for the modified instrument.

4. The apparatus guarantees high specificity, demonstrability, and reproducibility of the results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature cited

  1. A. D. Aleksandrov, N. G. Anufrieva, T. I. Zhmyrina, and A. F. Moroz, Zh. Mikrobiol., No. 1, 14 (1984).

  2. A. A. Babaev, L. P. Mel'nikova, and Z. L. Dzhabarova, Vopr. Virusol., No. 5, 577 (1983).

  3. V. A. Burlev and V. I. Sobolev, Collection of Papers by Inventors and Efficiency Experts [in Russian], Moscow (1984), p. 24.

  4. I. P. Gontar', S. M. Farber, V. I. Efremenko, et al., Zh. Mikrobiol., No. 3, 55 (1984).

  5. L. B. Kozlov, S. G. Kostylev, and A. D. Evtushenko, Vopr. Virusol., No. 5, 571 (1983).

  6. N. N. Piven' and V. I. Ilyukhin, Zh. Mikrobiol., No. 4, 78 (1981).

  7. V. I. Sobolev, A. V. Bashtanov, N. K. Akkuratova, et al., Investigation of Optimal Principles of Design of Electrophoretic Instruments for Immunologic Investigations. Research Report, [in Russian], Leningrad (1982).

  8. V. I. Sobolev, A. V. Bashtanov, V. A. Burlev, et al., Medical Engineering News [in Russian], Moscow (1980), p. 24.

  9. B. L. Cherkasskii, A. G. Knop, and V. Yu. Markov, Zh. Mikrobiol., No. 1, 95 (1984).

  10. G. C. Klein, J. Clin. Microbiol.,11, 27 (1980).

    Google Scholar 

Download references

Authors

Additional information

All-Union Research and Design Institute for Medical Laboratory Equipment, Leningrad. Translated from Meditsinskaya Tekhnika, No. 5, pp. 44–46, September–October, 1986.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sobolev, V.I., Bashtanov, A.V., Burlev, V.A. et al. The use of immunoelectrophoretic apparatus for rapid diagnosis. Biomed Eng 20, 179–181 (1986). https://doi.org/10.1007/BF00563387

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00563387

Keywords

Navigation