Abstract
The connection between the field nonuniformity at an electrode and the distribution of discharge initiation sites over its surface is described. The results of experiments on the breakdown of transformer oil in the cone-plane system of electrodes is analyzed within the framework of a multifractal model of the charge distribution [1]. The conclusion given in [1] that the regions with the maximum local field strength are not always the most probable sites for initiation of a discharge was experimentally confirmed. We observed the theoretically predicted transition of the discharge initiation sites at sharp points on the surface of a cone. For electrodes of stainless steel and transformer oil a value of the index relates the probability of initiation of a discharge to the local field strength was determined.
Similar content being viewed by others
References
M. D. Nosikov, V. R. Kukhta, and V. V. Lopatin, Izv. Vuzov Fiz., No. 11, 96–99 (1993).
E. Jahnke, F. Emde, and F. Lem, Special Functions [Russian translation], Nauka Moscow (1977).
N. K. Kapishinkov and V. Ya. Ushakov, ÉOM, No. 6, 9–11 (1979).
A. P. Avrorov and V. V. Vorob'ev, Novosibirsk (1983), (preprint IYaF SO Akad. Nauk SSSR No. 83–69).
Additional information
Scientific — Research Institute of High Voltages at Tomsk Polytechnic Institute. Translated from Izvestiya Vysshikh Uchebnykh Zavedenii, Fizika, No. 4, pp. 32–35, April, 1995.
Rights and permissions
About this article
Cite this article
Kukhta, V.R., Lopatin, V.V. & Noskov, M.D. Relation between the distribution of initiation sites of a discharge and the field nonuniformity at an electrode. Russ Phys J 38, 355–358 (1995). https://doi.org/10.1007/BF00560097
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00560097