Abstract
Experimental data on the corrosion cracking resistance of high-strength steel with a yield limit σ0.2 ℞ 1000 MPa in 3.5 % NaCl solution are presented. It is shown that cracking resistance can be estimated by using the so-called net rated fracture stresses. Corrosion cracking in the surface layers of the metal operating in contact with the medium is explained by the suppression of the processes of plastic deformation.
Similar content being viewed by others
References
V. N. Malyshev, “Estimation of the corrosion-mechanical strength of structural steels by rated fracture stresses,”Sudostroit. Prom., Ser. Metalloved. Metallurg., Issue 11, 43 (1989).
Additional information
Central Scientific-Research Institute of Structural Materials “Prometei,” St. Petersburg. Translated from Fiziko-Khimicheskaya Mekhanika Materialov, Vol. 30, No. 1, pp. 42–45, January–February, 1994.
Rights and permissions
About this article
Cite this article
Malyshev, V.N., Potapov, V.V. Distinctive features of corrosion cracking of high-strength steels. Mater Sci 30, 38–41 (1995). https://doi.org/10.1007/BF00559014