Polarographic determination of the lead content of precipitation baths in viscose manufacturing

  • I. P. Smirnov
Manufacturing Control
  • 17 Downloads

Conclusions

A procedure has been developed for determining microquantities of lead in precipitation baths in visose manufacturing, in the presence of other elements, using differentially pulsed polarography.

The total error in the procedure is ±7%.

Keywords

Polymer Precipitation Total Error Lead Content Polarography 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Literature cited

  1. 1.
    G. G Finger, Spinning and Finishing of Viscose Fibres [in Russian], Khimiya, Moscow (1969).Google Scholar
  2. 2.
    B. Ya. Kaplan, Pulsed Polarography [in Russian], Khimiya, Moscow (1978).Google Scholar
  3. 3.
    N. G. Polyanskii, Lead, in series “Analytical Chemistry of the Elements” [in Russian], Nauka, Moscow (1986).Google Scholar
  4. 4.
    A. K. Charykov and N. N. Osipov, Zh. Anal. Khim., 38, No. 3, 556–561 (1983).Google Scholar