Abstract
In tensile tests on lubricated bundles of a few hundred parallel E-glass fibres it is shown that individual fibre breaks, to the last fibre in the bundle, can be detected using acoustic emission (AE). By this means the single-fibre strength distribution is deduced. Relationships are obtained between some AE signal parameters and the fibre fracture stress which are consistent with theoretical expectations. Studies are made of the distribution of fibre break locations, the occurrences of multiple (stimulated) fibre breaks and the attenuation of the AE signals.
Similar content being viewed by others
References
W. Weibull, J. Appl. Mech. 18 (1951) 293.
Z. Chi, T. -W. Chou and G. Shen, J. Mater. Sci. 19 (1984) 3319.
K. E. Evans, B. D. Caddock and K. L. Ainsworth, ibid. 23 (1988) 2926.
A. Kelly and L. F. McCartney, Proc. Roy. Soc. A374 (1981) 475.
H. T. Corten, in“Modern Composite Materials” (Addison Wesley, 1967) p. 52.
M. A. Hamstad, J. Acoustic Emission 5 (1986) 95.
A. G. Hankin, Personal communication (1988).
M. A. Hamstad and R. L. Moore, J. Compos. Mater. 20 (1986) 47.
F. Fuwa, A. R. Bunsell and B. Harris, J. Phys. D. 9 (1976) 363.
A. G. Beattie, J. Acoustic Emission 2 (1983) 95.
M. Kumosa, D. Hull and J. N. Price, J. Mater. Sci. 22 (1987) 331.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cowking, A., Attou, A., Siddiqui, A.M. et al. Testing E-glass fibre bundles using acoustic emission. J Mater Sci 26, 1301–1310 (1991). https://doi.org/10.1007/BF00544469
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF00544469