Advertisement

Fresenius' Zeitschrift für analytische Chemie

, Volume 287, Issue 1, pp 19–22 | Cite as

Automated separation and preconcentration of copper(II) from natural waters using a column treatment

  • M. M. Guedes da Mota
  • F. G. Römer
  • B. Griepink
Original Papers

Summary

A comparison is made between two automated column procedures for the separation and preconcentration of Cu(II) from natural waters. The column materials were: an anion-exchange resin and 8-hydroxyquinoline immobilized on a glass support. 8-Hydroxyquinoline showed about the same performance as the ion exchange resin, but was less time and labour consuming. Cu(II) determinations at the ppb level were checked with standard additions and the results were moreover compared with those obtained by another method.

Key words

Abtrennung von Kupfer(II) aus Wasser Säulenverfahren Ionenaustauscher, Oxin, AAS-Bestimmung 

Automatische Trennung und Anreicherung von Kupfer(II) aus natürlichen Wässern mit Hilfe von Trennsäulensystemen

Zusammenfassung

Zwei automatisierte Trennsäulensysteme zur Abtrennung und Anreicherung von Kupfer(II) aus natürlichen Wässern wurden verglichen. Das aktive Material war ein Anionaustauscher und 8Hydroxychinolin auf Glas. 8-Hydroxychinolin zeigte etwa dieselben Ergebnisse wie der Anionaustauscher, benötigte aber weniger Arbeits- und Zeitaufwand. Cu(II)-Bestimmungen im ppb-Bereich wurden nach dem Verfahren der Standardzugabe geprüft und die Ergebnisse mit denen einer anderen Methode verglichen.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Florence, T. M.: J. Electronal. Chem. 27, 273 (1970)Google Scholar
  2. 2.
    Fonds, A. W., van den Eshof, A. J.: H2O 6, 465 (1973)Google Scholar
  3. 3.
    Guedes da Mota, M. M., Römer, F. G., Reissenweber, H., van de Weerdhof, T., Lanning, Chr., Griepink, B.: Fresenius Z. Anal. Chem. 285, 238 (1977)Google Scholar
  4. 4.
    Hendrikx-Jongerius, C., de Galan, L.: Anal. Chim. Acta 87, 259 (1976)Google Scholar
  5. 5.
    Korkisch, J., Sorio, A.: Anal. Chim. Acta 76, 393 (1975)Google Scholar
  6. 6.
    Leyden, D. E., Luttrell, G. H.: Anal. Chem. 47, 1612 (1975)Google Scholar
  7. 7.
    Leyden, D. E., Luttrell, G. H., Sloan, A. E., DeAngelis, N. J.: Anal. Chim. Acta 84, 97 (1976)Google Scholar
  8. 8.
    van Oort, W. J., van den Bergen, V. W. J., Griepink, B.: Fresenius Z. Anal. Chem. 269 184 (1974)Google Scholar
  9. 9.
    van Oort, W. J.:Titrations as a possibility for measuring in flow systems-an exploration-. Thesis, Utrecht 1976Google Scholar
  10. 10.
    Slania, J.: Private communicationGoogle Scholar
  11. 11.
    Sugawara, K. F., Weetall, H. H., Schucker, G. D.: Anal. Chem. 46, 489 (1974)Google Scholar

Copyright information

© Springer-Verlag 1977

Authors and Affiliations

  • M. M. Guedes da Mota
    • 1
  • F. G. Römer
    • 1
  • B. Griepink
    • 1
  1. 1.Laboratory for Analytical Chemistrythe UniversityUtrechtThe Netherlands