Skip to main content
Log in

Radiokomplexometrische Bestimmung von Cyanocobalamin

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

For the determination of cyanocobalamin the following method is recommended: the compound is decomposed by ozone, radioactive 60Co is added, cobalt is adsorbed on a cation exchanger and the activity is measured. After reaction with a substoichiometric quantity of EDTA the residual activity is measured again. The difference of activities is proportional to the original amount of cyanocobalamin, which is read from a calibration curve. Satisfactory results are obtained.

Zusammenfassung

Zur Bestimmung von Cyanocobalamin wird folgendes Verfahren empfohlen: Das aus der Verbindung mit Ozon in Freiheit gesetzte Kobalt wird mit radioaktivem 60Co versetzt und an einem Kationenaustauscher adsorbiert, dessen Aktivität gemessen wird. Durch Reaktion mit einer substöchiometrischen Menge an ÄDTA wird dann eine aliquote Menge des Kobalts vom Austauscher gelöst und die restliche Aktivität gemessen. Die Differenz der Aktivitäten ist der ursprünglichen Menge an Cyanocobalamin proportional, die aus einer Eichkurve entnommen wird. Das Verfahren ergibt befriedigende Werte.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Braun, T., and J. Tölgyessy: The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Pittsburgh, Febr. 20–25, 1966; Nucl. Applications 3, 383 (1967).

    Google Scholar 

  2. — — and J. Konečný: Acta Chim. Acad. Sci. Hung. 49, 131 (1966).

    Google Scholar 

  3. Konečný, J., u. J. Tölgyessy: Chem. Zvesti 20, 692 (1966).

    Google Scholar 

  4. — —: Radioisotopy 7. 87 (1966).

    Google Scholar 

  5. - - Sborník Prírodovedeckej fatulty UK, Bratislava (im Druck) (1966).

  6. — — and T. Braun: Conference on Application of Physico-Chemical Methods in Chemical Analysis, Budapest, April 20–23, 1966. Proc. of the Anal. Chem. Conf. 2, 471 (1966).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Konečný, J., Tölgyessy, J. & Šaršúnová, M. Radiokomplexometrische Bestimmung von Cyanocobalamin. Z. Anal. Chem. 232, 343–346 (1967). https://doi.org/10.1007/BF00533839

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00533839

Navigation