Skip to main content
Log in

Entwicklung eines universellen, preiswerten Interfaces zur Kopplung von Personal-Computern mit Analysengeräten

Teil II. Rechnerunterstützte Polarographie

Development of a universal, low-cost interface for coupling personal computers with analytical devices

Part II. Computer assisted polarography

  • Originalarbeiten
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

A simple and inexpensive method is proposed for the combination of a polarographic set with a personal computer. This technique allows a passive data transfer and a following mathematical treatment of the data. An algorithm to locate peaks is developed. Because of the high arithmetic speed it can be used for real time processes. A further advantage of the method described is that this algorithm can be used universally, because it is not based on mathematical equations depending on the experimental method used.

Zusammenfassung

Es wird ein einfaches und kostengünstiges Verfahren zur Kopplung eines Polarographen mit einem Personal-Computer vorgestellt, womit eine passive Datenübernahme und anschließende mathematische Behandlung der Meßwerte ermöglicht wird. Zur Lokalisation von Peaks wird ein Algorithmus beschrieben, der sich infolge schneller Rechenzeiten durch Echtzeitverarbeitung auszeichnet. Außerdem ist er universell anzuwenden, da er nicht auf mathematischen Gleichungen beruht, die den verwendeten Methoden (z. B.: Polarographie oder Photometrie) zugrunde liegen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Barry DM, Meites L (1974) Anal Chim Acta 68:435–445

    Google Scholar 

  2. Bond AM, Grabaric BS (1976) Anal Chem 48:1624–1628

    Google Scholar 

  3. Bos M (1980) Anal Chim Acta 122:193–200

    Google Scholar 

  4. Buschmann N, Rump T, Umland F (1984) Fresenius Z Anal Chem 318:509–510

    Google Scholar 

  5. Camman K, Anderson JT (1982) Fresenius Z Anal Chem 310:45–50

    Google Scholar 

  6. Ebel S, Glaser E, Richter M, Surmann P (1981) Fresenius Z Anal Chem 305:204–208

    Google Scholar 

  7. Gomez-Beltran F, Salas A (1978) Anal Chim Acta 103:263–267

    Google Scholar 

  8. Gutknecht WF, Perone SE (1970) Anal Chem 42:906–917

    Google Scholar 

  9. Karchmer JH, Walker MT (1954) Anal Chem 26:271–280

    Google Scholar 

  10. Kavel H, Umland F (in Vorbereitung)

  11. Lehmann MS, Larsen FK (1974) Acta Cryst A 30:580–584

    Google Scholar 

  12. Meites T, Meites L (1972) Talanta 19:1131–1139

    Google Scholar 

  13. Savitzky A, Golay MJE (1964) Anal Chem 36:1627–1639

    Google Scholar 

  14. Wolf D (1963) J Electroanal Chem 5:186–194

    Google Scholar 

  15. Ziegler E (1973) Computer in der instrumentellen Analytik. Akademische Verlagsgesellschaft, Frankfurt

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Teil I: Fresenius Z Anal Chem (1984) 318:509–510

Nach der Detektion der Peakbasis folgt die Approximation der Basislinie mittels geeigneter Verfahren [5, 10] und die anschließende Berechnung der Peakhöhe bzw. Peakfläche.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Buschmann, N., Kavel, H., Rump, T. et al. Entwicklung eines universellen, preiswerten Interfaces zur Kopplung von Personal-Computern mit Analysengeräten. Z. Anal. Chem. 318, 592–596 (1984). https://doi.org/10.1007/BF00529117

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00529117

Navigation