Über die Konsistenz der normalen und ödematösen Haut

  • Published:
Archiv für klinische und experimentelle Dermatologie Aims and scope Submit manuscript

Summary

A new device for determining the consistency of human skin is described. In principle it consists of a circular impress of variable diameter and adjustable compression depth by means of which the thereby caused compression pressure—the relative outward bulge of the skin in the center of the circle—can be measured. By first weighting the measuring apparatus in the center, the relative depression of the central area to the perimeter—or the mutual influence of both occurrances upon each other—can be measured.

The first orienting investigations concerning measurements of edema or swelling skin are reported according to performed experiments designed to illustrate the principle and the mutual influence of individual elements and factors involved in the measurement. The individual therapeutic measures can be distinguished from each other not only through the intensity of effectiveness, but by means of varied changes in the individual “experiment-requirements”, certain reference points concerning the reaction mechanism are revealed.

Zusammenfassung

Es wird eine neue Einrichtung zur Bestimmung der Konsistenz der menschlichen Haut beschrieben. Das Prinzip beruht auf einer kreisförmigen Impression mit unterschiedlichem Durchmesser und einstellbarer Kompressionstiefe, wobei der auftretende Kompressionsdruck bzw. die relativ Vorwölbung der Haut im Zentrum des Kreises gemessen werden kann. Durch Vorbelastung des Meßstiftes im Zentrum kann umgekehrt auch die relative Einsenkung dieser Stelle gegenüber dem äußeren Kreis gemessen werden bzw. die gegenseitige Beeinffussung beider Vorgänge.

Nach Modellversuchen zur Erläuterung des Prinzipes und der gegenseitigen Beeinflussung der einzelnen an der Messung beteiligten Elementen und Faktoren werden erste orientierende Untersuchungen über Messungen an Ödemen bzw. der gequollenen Haut mitgeteilt. Es lassen sich dabei die einzelnen therapeutischen Maßnahmen nicht nur bezüglich der Intensität der Wirkung unterscheiden, sondern es ergeben sich auch Anhaltspunkte für den Wirkungsmechanismus aus der unterschiedlichen Änderung in den einzelnen Versuchsbedingungen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Brünjes, H.: Frequenzleitfähigkeit und Hautspannung. Inaug.-Diss., Göttingen 1954.

  2. Fischer, H., u. W. Schneider: Zur Messung von Schwellungszuständen der Unterschenkel mit Hilfe des Ultraschall-Impulsecho-Verfahrens. Angiologica 3, 259–267 (1966).

    Google Scholar 

  3. Friederich, H. C., u. K. D. Mörike: Über die Dehnbarkeit und Verschiebbarkeit der Haut des Gesichtes beim Menschen unter klinischen und experimentellen Aspekten. Arch. klin. exp. Derm. 215, 496–512 (1963).

    Google Scholar 

  4. Göpfert, H.: Allgemeine Physiologie der Haut. In: Dermatologie u. Venerologie, Bd. I/1, S. 130–192. Stuttgart: Thieme 1961.

    Google Scholar 

  5. Jochims, J.: Grundzüge einer einfachen klinischen Prüfung der Hautdehnung. Arch. Kinderheilk. 133, 97–103 (1947).

    Google Scholar 

  6. Kaus, H.: Genese und diagnostischer Wert von unter Saugglocken entstandenen Hautblutungen. Z. ges. exp. Med. 124, 448–464 (1954).

    Google Scholar 

  7. Keller, P.: Mechanische Eigenschaften der Haut. In: Handb. d. Haut- u. Geschl.-Kr., Ergänzungswerk I/3, S. 1–35. Berlin, Göttingen, Heidelberg: Springer 1963.

    Google Scholar 

  8. Kirk, E., and S. A. Kvorning: Quantitative measurements of the elastic properties of the skin and subcutaneous tissue in young and old individuals. J. Geront. 4, 273–284 (1949).

    Google Scholar 

  9. Külbs: zit. bei Keller, P.

    Google Scholar 

  10. Lewis, H. E., J. Mayer, and A. A. Pandisojo: Recording skin fold calibres for the determination of subcutaneous edema. J. Lab. clin. Med. 66, 154–160 (1965).

    Google Scholar 

  11. Paerisch, I., u. M. Paerisch: Messung der Schichtstärke des menschlichen Unterhautfettgewebes mit dem Ultraschall-Impulsechoverfahren. Pflügers Arch. ges. Physiol. 276, 437–444 (1962/63).

    Google Scholar 

  12. Schade, H.: Untersuchungen zur Organfunktion des Bindegewebes. 1. Die Elastizitätsfunktion des Bindegewebes und die initiale Messung ihrer Störungen. Z. exp. Path. Ther. 11, 369–399 (1912).

    Google Scholar 

  13. Stüttgen, G.: Die normale und pathologische Physiologie der Haut, Stuttgart: Fischer 1965.

    Google Scholar 

  14. Tronnier, H.: Zur Standardisierung von Waschversuchen an der menschlichen Haut. Fette, Seifen, Anstrichm. 67, 512–514 (1965).

    Google Scholar 

  15. —, u. E. Ailinger: Zur Prüfung des Einflusses von Gewebsextrakten auf die menschliche Haut unter besonderer Berücksichtigung einer neuen Methode. Parfüm. u. Kosmetik 40, 25–29 (1959).

    Google Scholar 

  16. —, u. H. Fischer: Zur Differenzierung cutaner Zustandsänderungen unter verschiedenen Stauungsbedingungen. Dermatologica (Basel) 131, 199–212 (1965).

    Google Scholar 

  17. —, u. H. Kuhn-Bussius: Kritische Übersicht zur Frage der Messung der Resonanzfrequenz der Haut unter Berücksichtigung der Auswertung und der Streubreite der Methodik. Arch. klin. exp. Derm. 217, 563–576 (1963).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof. A. Proppe, Kiel, zum 60. Geburtstag gewidmet.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tronnier, H. Über die Konsistenz der normalen und ödematösen Haut. Arch. klin. exp. Derm. 228, 372–384 (1967). https://doi.org/10.1007/BF00520177

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00520177

Navigation